F.R. Precautions 3
Be sure to read before handling.
Maintenance
1.
When disassembly or installation is required during the
maintenance, repair, or replacement of a device, be sure to follow
the instructions provided in the instruction manual or safety
instructions in this catalog.
2.
Perform periodical inspections to detect any cracks, scratches, or
other deterioration of the transparent resin bowl of the air filter
and filter regulator.
Replace with a new bowl or metal bowl when any kind of
deterioration is found, otherwise this can cause damage.
3.
Perform periodical inspections to detect dirt on the transparent
resin bowl of the air filter and filter regulator. When you find dirt
on any of the above devices, clean with a household neutral
detergent. Do not use other cleaning agents, otherwise this can
cause damage.
4. Air filter
1) Replace the element every 2 years or when the pressure drop
becomes 0.1 MPa, whichever comes first, to prevent damage
to the element.
2) Release accumulated condensate periodically before it reaches
the maximum capacity. Condensate that flows out to the outlet
side can cause malfunctions.
5. Mist separator and micro mist separator
1) Replace the element every 2 years or when the pressure drop
becomes 0.1 MPa, whichever comes first, to prevent damage
to the element.
2) Release accumulated condensate periodically before it reaches
the maximum capacity. Condensate that flows out to the outlet
side can cause malfunctions.
1.
Perform periodical inspections of the filter element and replace it
as necessary. Check the element whenever the outlet pressure
drops below normal or air does not flow smoothly during
operation.
2. Regulator and filter regulator
Check the sliding part or seat of the internal valve when a setting
malfunction or relief leakage occur and temporary or emergency
repairs need to be made.
802
Warning
Caution