3. SIGNALS AND WIRING
3.2.2 Internal speed control mode
LZ
Plate
Servo amplifier
T rouble (Note 6)
Electromagnetic
brake interlock
9
ALM
10
SA
11
RD
12
MBR
CN1
Speed reached
Ready
Encoder A-phase pulse
(differential line driver)
15
LA
16
LAR
17
LB
18
LBR
14
LG
21
OP
SD
2m max.
Encoder B-phase pulse
(differential line driver)
Control common
Encoder Z-phase pulse
(open collector)
Encoder Z-phase pulse
(differential line driver)
19
20
LZR
CN1
1
13
DICOM
DOCOM
10m max.
USB cable
(option)
CN3
MR Configurator
Personal
computer
24VDC
RA1
RA 2
RA 3
RA 4
8
4
3
7
Forced stop
Servo-on
Reset
Forward rotation
start
Reverse rotation
start
(Note 3, 5)
5
6
Speed selection 1
EM1
SON
RES
ST1
ST2
SP1
(Note 9,
10, 12)
(Note 4, 9)
(Note 7)
(Note 2)
(Note 9, 11)
10m max.
(Note 1)
(Note 8)
(Note 7)
Control common
CNP1
Note 1. To prevent an electric shock, always connect the protective earth (PE) terminal (terminal marked
) of the driver to the
protective earth (PE) of the control box.
2. Connect the diode in the correct direction. If it is connected reversely, the driver will be faulty and will not output signals,
disabling the emergency stop and other protective circuits.
3. The forced stop switch (normally closed contact) must be installed.
4. Supply 24VDC 10% 200mA current for interfaces from the outside. 200mA is the value applicable when all I/O signals are used.
The current capacity can be decreased by reducing the number of I/O points. Refer to section 3.8.2 (1) that gives the current
value necessary for the interface.
5. When starting operation, always switch on the forced stop (EM1). (Normally closed contacts)
6. Trouble (ALM) turns on in normal alarm-free condition.
7. The pins with the same signal name are connected in the driver.
8. Use LEC-MRC2E (Ver.1.52E or later).
9. This diagram is for sink I/O interface. For source I/O interface, refer to section 3.8.3.
10. The assigned signals can be changed using the settings of parameter No.PD03 to PD14.
11. The assigned signals can be changed using the settings of parameter No.PD15 to PD18.
12. The forward rotation stroke end (LSP) and the reverse rotation stroke end (LSN) automatically switch ON if not assigned to the
external input signals.
13. Encoder Z-phase pulse will correspond to the differential line driver system and the open collector system.
If the encoder Z-phase pulse is open collector method, it supports only to the sink (NPN) type interface. It does not correspond
to the source (PNP) type interface.