1 - 7
1. FUNCTIONS AND CONFIGURATION
1.3 Driver standard specifications
Driver
LECSA
□
-
□
Item
S1
S3
S4
S1
S3
Output
Rated voltage
3-phase 170VAC
Rated current [A]
1.1
1.6
2.8
1.1
1.6
Main circuit
power supply
Voltage/frequency
1-phase 200VAC to 230VAC, 50/60Hz
1-phase 100VAC to 120VAC,
50/60Hz
Rated current [A]
1.5
2.4
4.5
3.0
5.0
Permissible voltage
fluctuation
1-phase 170VAC to 253VAC
1-phase 85VAC to 132VAC
Permissible frequency
fluctuation
Within 5%
Power supply capacity
Refer to section 10.2
Inrush current
Refer to section 10.5
Control circuit
power supply
Voltage
24VDC
Rated current [A]
0.5
Permissible voltage
fluctuation
Within 10%
Power consumption [W]
10
Interface
power supply
Voltage
24VDC 10%
Power supply capacity [A]
0.2 (Note)
Control System
Sine-wave PWM control, current control system
Dynamic brake
Built-in
Protective functions
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal
relay), servo motor overheat protection, encoder error protection, regenerative error
protection, undervoltage, instantaneous power failure protection, overspeed protection,
excessive error protection
Structure
Natural-cooling, open (IP rating: IP20)
Close mounting
When mounting the diver closely, operate them at the ambient temperature of 0°C to 45°C or
at 75% or less of the effective load ratio.
Environmental
conditions
Ambient
temperature
In
operation
[°C]
0 to 55 (non-freezing)
[°F]
32 to 131 (non-freezing)
In
storage
[°C]
-20 to 65 (non-freezing)
[°F]
-4 to 149 (non-freezing)
Ambient
humidity
In operation
90%RH or less (non-condensing)
In storage
Ambience
Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude
Max. 1000m (3280 ft) above sea level
Vibration
5.9 [m/s2] or less, 10 to 55Hz (directions of X, Y and Z axes)
Mass
[kg]
0.6
0.6
0.7
0.6
0.6
[lb]
1.32
1.32
1.54
1.32
1.32
Note. 0.2A is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of I/O
points.