Status LEDs
The S1500e and S1502e have a single LED for system status. On the
other hand, the S1504e and S1508e units have one system status
LED and four or eight video status LEDs respectively. All these LEDs
are bicolor (red-green).
The following power-up conditions on the system status LED are
abnormal:
Warning
LED not lit: Check the power supply and cabling. If power is available and the LED
stays off, call SmartSight technical support for assistance.
Steady red LED: There is an internal error that prevents the unit from starting
normally. Power down and power back up the unit once. If the condition persists,
proceed to a firmware update (for details, refer to the
SConfigurator User
Manual
). If the update fails or the condition persists after the update, call
SmartSight technical support for assistance.
Flashing red LED (2 second intervals): There is an internal error that prevents the
unit from operating normally. This situation may happen after a firmware update
or after the first boot-up. Power down the unit and call SmartSight technical
support for assistance.
Flashing green-red LED not during a firmware update (S1500e and S1502e only):
The unit is in backup mode; you will need to perform a firmware update using a
serial connection.
Содержание S1500e Series
Страница 1: ...S1500e Series Quick Installation Guide...
Страница 2: ......
Страница 3: ...S1500eTM Series Firmware Release 2 60 3 0 Quick Installation Guide...
Страница 12: ......
Страница 26: ......
Страница 45: ...33 Unit Description Form...
Страница 47: ...SmartSight Networks Inc 1800 Berlier Street Laval Quebec H7L 4S4 Canada...