T4 (053B) Series
Installation Guide
CD354/220116
Smartscan Ltd
30
Learn Setting - 6
Not applicable (do not select).
Learn Setting 7 - Clear All Learnt
Clears all functions applied in the Learn mode, returning the system to its original
factory settings.
Use the following steps to clear any learnt functions selected:
1. Disconnect power to the light curtain.
2. Configure the DIP switches as per the diagram to the left.
3. Reinstate power to the light curtain. All LEDs on the RX
head are on to indicate that the Clear mode is active and
all learnt functions have now been cleared.
4. Disconnect power to the light curtain.
5. Set DIP switches as per the Direct Setting requirements.
6. Reinstate power to the light curtain. All LEDs revert back
to their normal functions and the original factory default
settings are applied.
1
2
3
4
5
6
ON OFF
Clear
(All Learned
settings)