Powering Up
Perform the following to power up the drive.
Apply external power by closing the main disconnect.
Close the two-pole breaker and all pushbutton breakers.
Verify the LCD on the Smartrise board and the Magnetek Drive powers up.
Figure 5: Breakers
KEB Motor Learn
Smartrise programs the KEB drive with factory defaults to properly communicate with the
controller. After factory testing, customer motor data (from customer’s EDF) is programmed
into the drive to provide an easier “out of box” installation.
Initial Setup
The complete motor data must be learned with the automated learn function.
The Motor Learn function can be found under the Tune Parameters group from the
Programming menu (Home > Prog > Tune Parameters > LL01).
Perform the following for initial setup.
Set Motor Tuning LL01 to Start.
Follow the instructions on the LCD screen.
•
On the MR board, Toggle DIP 6A (Top bank) to on to start the tune process
•
Once complete, turn off DIP 6A.