PREMIER - 2 USERS TECHNICAL MANUAL
General information
Manager factory code 1-2-3-4-5-6.
A valid entry is followed by a double signal.
An invalid entry is followed by a long signal.
After 5 seconds without entry, current operation will be cancelled.
Penalty
After entry of 4 consecutive invalid codes the lock will be blocked for 5 minutes (penalty).
During penalty the LED flashes every 10 seconds.
During penalty any key pressed causes a long signal.
After penalty, entry of 2 more invalid codes restarts the 5 minutes blocking period.
Low battery signal
A series of signals indicates that the battery is weak and must be replaced.
Only use brand new 9V ALKALINE batteries.
Open the lock
• Enter the code (double signal).
• If time delay has not been set open the lock within 4 seconds.
• If time delay has been set wait for time delay counting: LED flashes every 2 seconds.
• A signal every 2 seconds indicates time delay counting is over and open window started.
• Enter the code (double signal) and open the lock within 4 seconds.
Change code
(only change the code with safe door open).
• Press and hold 0 until double signal.
• Enter current user code (double signal).
• Enter new code (double signal) and repeat new code to confirm (double signal).
• Code has been changed: try new code with door open.
In case of any error (long signal) the old code remains valid.
Safety reference:
All codes are to be securely stored.
Do not use personal data (i.e. birthdays, phone numbers, etc.).
Change factory code before you start using the safe.
Install the user
• Press and hold 1 until double signal.
• Enter Manager code (double signal).
• Enter new user code (double signal) and repeat new code to confirm (double signal).
• User code has been installed: try new code with door open.
In case of any error (long signal) user code has not been installed.
Delete the user
• Press and hold 3 until double signal.
• Enter Manager code (double signal).
• User code has been deleted.
of
1
2