HRC200 Industrial Remote Control User Manual Page 11 of 16
4.6
RECEIVER WIRING TERMINAL
Fig.5 Mask Diagram
Table 9 Wiring Terminal Description
No.
Function
Cable Size
Remark
1
COM
0.75mm
2
Relay common port.
2
AUX. OUTPUT5
0.75mm
2
Normally open volt-free output, capacity
DC30V/2A.
3
AUX. OUTPUT4
0.75mm
2
Normally open volt-free output, capacity
DC30V/2A.
4
AUX. OUTPUT3
0.75mm
2
Normally open volt-free output, capacity
DC30V/2A.
5
AUX. OUTPUT2
0.75mm
2
Normally open volt-free output, capacity
DC30V/2A.
6
AUX. OUTPUT1
0.75mm
2
Normally open volt-free output, capacity
DC30V/2A.
7
TR
/
RS485 communication line uses twisted
shielded pair line. When 120Ω terminal
matching resistor is required, A(+) and TR
terminal should be short connected.
8
RS485 A(+)
0.5mm
2
9
RS485 B(-)
0.5mm
2
10
AUX. INPUT2
0.75mm
2
B- connected is active.
11
AUX. INPUT1
0.75mm
2
B- connected is active.
12
B+
0.75mm
2
Externally connects power positive.
13
B-
0.75mm
2
Externally connects power negative.