Smartgen HGM501 Скачать руководство пользователя страница 4

HGM501Genset Controller 

HGM501 Genset Controller              Version V1.0              2012-07-10                  Page 4 of 15 
 

1.  OVERVIEW 

HGM501 gen-set controller

 is smart digital controller for control and protection 

of  single-engine  gen-sets.  It  can  carry  out  start/stop,  data  measurement,  alarm 

indication,  shutdown  protection  and  other  functions.  The  controller  is  fitted  with 

LED indicators; it is reliable and easy to use. 

HGM501  gen-set  controller

  contains  the  microprocessor  allows  precise 

measurement  of  multiple  parameters,  which  can  be  configured  using  controller 

front panel. With simple wiring, compact structure and high reliability, HGM501 can 

be widely used for data display and fault protection of a large number of diesel and 

petrol generator sets. 

2.  PERFORMANCE AND CHARACTERISTICS 

1.  Two  specialized  LED  displays:  single  phase  voltage  display  and  total  active 

power  voltage  display  (calculated  using  single  phase  power,  taking  load  as 

balanced); 

2.  Multifunction  LED  display  that  can  be  switched  between  single  phase 

frequency,  single  phase  current,  battery  voltage,  total  running  time (max  999 

hours), engine and generator temperature; 

3.  Under voltage, over voltage, under frequency, over frequency, over load, over 

temperature  protection,  starting  with  flashing  lights  alarm  and  followed  by 

shutdown protection after alarm delay; 

4.  Low  oil  pressure  digital  input  that  immediately  shuts  down  the  generator  in 

case of low oil pressure; 

5.  Displayed parameters can be selected using touch-buttons; 

6.  Wide selection of temperature sensor types in settings; 

7.  All  the  parameters  can  be  set  via  front  panel  for  easy  and  convenient 

operation; 

8.  Modular  design,  anti-flaming  ABS  plastic  enclosure,  compact  structure, 

convenient embedded installation. 

Содержание HGM501

Страница 1: ...HGM501 Gen set Controller USER MANUAL Smartgen Technology...

Страница 2: ...ronic means or other without the written permission of the copyright holder Smartgen Technology reserves the right to change the contents of this document without prior notice Version History Date Ver...

Страница 3: ...NICAL DATA 5 4 OPERATION 6 4 1 BUTTON DESCRIPTION 6 4 2 START STOP OPERATION 7 4 2 1 STARTING PROCEDURE 7 4 2 2 STOPPING PROCEDURE 7 5 AUTO PROTECTION 8 6 TERMINAL 9 7 CONFIGURABLE PARAMETERS 10 7 1 C...

Страница 4: ...RISTICS 1 Two specialized LED displays single phase voltage display and total active power voltage display calculated using single phase power taking load as balanced 2 Multifunction LED display that...

Страница 5: ...ase 4 wire L and N only AC 30V 360V ph N AC 30V 360V ph N AC 30V 360V ph N Alternator frequency 50 60Hz Start relay output 7A DC12V power supply output Fuel relay output 7A DC12V power supply output C...

Страница 6: ...alarm UP SCROLL 1 During parameter configuration pressing this button increases the set value 2 During normal operation press this button to switch to the upper LED DOWN SCROLL 1 During parameter conf...

Страница 7: ...6 Generator temp 7 Auto protection If on auto protection is enabled if not it is disabled 8 Run on indicator Fuel relay output indicator 9 Crank indicator Start output indicator 10 Engine oil warning...

Страница 8: ...g If the set value is exceeded by 5 7 5 and continuous for more than 3 hours then alarm shutdown will be initiated If the set value is exceeded by 7 5 10 and continues for more than 1 hours alarm shut...

Страница 9: ...after Safety On Delay when voltage frequency overload high temperature protection is initiated fuel output deactivates 6 TERMINAL HGM501 controller back panel is shown below Terminal connections desc...

Страница 10: ...lock START input 1 5mm2 Hand turn start start relay output Output activates when electric lock key is turned to START position 11 Start relay output 1 5mm2 Rated current 7A power supplied by terminal...

Страница 11: ...4 Select this according to the used sensor 7 2 PARAMETER CONFIGURATION Before using controller for the first time parameters must be configured rated voltage rated frequency rated power set values mus...

Страница 12: ...nd auto protection will continue to be enabled use or to make indicator off and press to disable auto protection When the light indicator is off it means that auto protection is disabled Enabling this...

Страница 13: ...sure all parameters are configured correctly and oil pressure light is on 3 Ensure the controller DC power supply is fused and correctly connected to the positive and negative of starter battery 4 Tak...

Страница 14: ...oller is designed for panel mounting it is held with the help of fixing clips Overall and cutout dimensions can be seen below unit mm 1 Battery Voltage Input NOTE HGM501 controller is suitable for 9 1...

Страница 15: ...n generator is on load C T secondary must not be open circuit 2 Withstanding voltage test CAUTION If withstanding voltage test is conducted after the controller has already been installed onto the con...

Отзывы: