ACC7200 Air Compressor Controller User Manual Page 75 of 77
14.17
VOLVO EDC4
Suitable engine models are TD520, TAD520 (optional), TD720, TAD720 (optional), TAD721, TAD722,
and TAD732. Engine type: Volvo-EDC4.
Table 40 Connector
Terminals of controller
Connector
Remark
Auxiliary Output 1
Extended
30A
relay,
providing battery voltage for
terminal 14; Fuse is 16A.
AUX. Output 1 is configured as “29: Fuel
Relay Output” (The configuration is factory
default).
Auxiliary Output 2
-
AUX. Output 2 is configured as “28:
Starting Relay Output” (The configuration
is factory default).
Connect to starter coil directly.
1
Connected to negative of battery.
CAN(H)
12
Using impedance 120Ω connecting line.
CAN(L)
13
Using impedance 120Ω connecting line.
14.18
VOLVO-EMS2
Volvo Engine models are TAD734, TAD940, TAD941, TAD1640, TAD1641, and TAD1642. Engine type:
Volvo-EMS2; and speed regulating can be realized.
Table 41 Engine CAN Port
Terminals of controller
Engine’s CAN port
Remark
Auxiliary Output 1
6
AUX. Output 1 is configured as “35 ECU
Stop”;
Auxiliary
Output 2
5
AUX. Output 2 is configured as “36 ECU
Power”;
3
Negative power.
4
Positive power.
CAN(H)
1(Hi)
Using impedance 120Ω connecting line.
CAN(L)
2(Lo)
Using impedance 120Ω connecting line.
NOTE:
When this engine type is selected, preheating time should be set to at least 3 seconds.