ACC7200 Air Compressor Controller User Manual Page 68 of 77
14.3
CUMMINS QSM11 (IMPORT)
Suitable for CM570 engine control module. Engine type is QSM11 G1, QSM11 G2. Engine type:
Cummins ISB.
Table 20 C1-pin Connector
Terminals of controller
C1 connector
Remark
Auxiliary Output 1
5&8
AUX. Output 1 is configured as “29: Fuel
Relay Output” (The configuration is factory
default).
Outside extended relay, make port 5 and
port 8 of C1 connected at fuel output.
Auxiliary Output 2
-
AUX. Output 2 is configured as “28:
Starting Relay Output” (The configuration
is factory default).
Connect to starter coil directly.
Table 21 3-pin Data Link Connector
Terminals of controller
3 pins data link connector
Remark
-
C
CAN
communication
shielding
line
(connect with ECU terminal only).
CAN(H)
A
Using impedance 120Ω connecting line.
CAN(L)
B
Using impedance 120Ω connecting line.
14.4
CUMMINS QSX15-CM570
Suitable for CM570 engine control module. Engine type is QSX15 etc. Engine type: Cummins
QSX15-CM570.
Table 22 50-pin Connector
Terminals of controller
50 pins connector
Remark
Auxiliary Output 1
38
AUX. Output 1 is configured as “29: Fuel
Relay Output” (The configuration is factory
default).
Oil spout switch.
Auxiliary Output 2
-
AUX. Output 2 is configured as “28:
Starting Relay Output” (The configuration
is factory default).
Connect to starter coil directly.
Table 23 9-pin Connector
Terminals of controller
9 pins connector
Remark
-
SAE J1939 shield-E
CAN
communication
shielding
line
(connect with ECU terminal only).
CAN(H)
SAE J1939 signal-C
Using impedance 120Ω connecting line.
CAN(L)
SAE J1939 return-D
Using impedance 120Ω connecting line.