Longo programmable controller LPC-2.C05

STANDARDS AND PROVISIONS: Standards, recommendations, regulations
and provisions of the country in which the devices will operate, must
be considered while planning and setting up electrical devices. Work
on 100 .. 240 V AC network is allowed for authorized personnel only.

DANGER   WARNINGS:   Devices   or   modules   must   be   protected   from
moisture, dirt and damage during transport, storing and operation.

WARRANTY   CONDITIONS:   For   all   modules   LONGO   LPC-2   –   if   no
modifications   are   performed   upon   and   are   correctly   connected   by
authorized   personnel   –   in   consideration   of   maximum   allowed
connecting power, warranty of 24 months is valid from the date of sale
to the end buyer, but not more than 36 months after delivery from
Smarteh. In case of claims within warranty time, which are based on
material   malfunctions   the   producer   offers   free   replacement.   The
method of return of malfunctioned module, together with description,
can be arranged with our authorized representative. Warranty does
not   include   damage   due   to   transport   or   because   of   unconsidered
corresponding   regulations   of   the   country,   where   the   module   is
installed.
This device must be connected properly by the provided connection
scheme in this manual. Misconnections may result in device damage,
fire or personal injury.
Hazardous  voltage  in  the  device  can  cause  electric  shock  and  may
result in personal injury or death.
NEVER SERVICE THIS PRODUCT YOURSELF!
This device must not be installed in the systems critical for life (e.g.
medical devices, aircrafts, etc.).

If the device is used in a manner not specified by the manufacturer,
the degree of protection provided by the equipment may be impaired.

Waste electrical and electronic equipment (WEEE) must be collected
separately!

LONGO LPC-2 complies to the following standards:

EMC: EN 61000-6-3:2007 + A1:2011, EN 61000-6-1:2007, EN 61000-
3-2:2006 + A1:2009 + A2: 2009, EN 61000-3-3:2013

LVD: IEC 61010-1:2010 (3

rd

 Ed.), IEC 61010-2-201:2013 (1

st

 Ed.)

Smarteh   d.o.o.   operates   a   policy   of   continuous   development.
Therefore we reserve the right to make changes and improvements to
any of the products described in this manual without any prior notice.

MANUFACTURER:
SMARTEH d.o.o.
Poljubinj 114
5220 Tolmin
Slovenia

ii

Содержание LPC-2.C05

Страница 1: ...USER MANUAL Longo programmable controller LPC 2 C05 GSM module Version 5 SMARTEH d o o Poljubinj 114 5220 Tolmin Slovenia Tel 386 0 388 44 00 e mail info smarteh si www smarteh si...

Страница 2: ...Longo programmable controller LPC 2 C05 Written by SMARTEH d o o Copyright 2012 SMARTEH d o o User Manual Document Version 005 July 1 2012 i...

Страница 3: ...ot include damage due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection s...

Страница 4: ...o programmable controller LPC 2 C05 1 DESCRIPTION 1 2 FEATURES 2 3 INSTALLATION 3 3 1 Connection scheme 3 3 2 Mounting instructions 5 3 3 Module labeling 7 4 TECHNICAL SPECIFICATIONS 8 APPENDIX A PROG...

Страница 5: ...M card If the phone numbers are stored in the international notation with country code then the prefix must start with 00 and not with symbol e g Slovenian international code is 00386 When LPC 2 C05 m...

Страница 6: ...Figure 1 LPC 2 C05 communication module Table 1 Technical data Dual band 900 1800 MHz Optional RS 232 communication port 9600 bps 8 bits one stop bit no parity no flow control reserved for external A...

Страница 7: ...me Figure 2 Connection scheme Table 2 ANT ANT Antenna connector SMA F GSM antenna SMA M Table 3 SIM CARD SIM CARD SIM card connector Table 4 K1 Internal BUS Data DC power supply Connection to I O modu...

Страница 8: ...FF power off Blink once SIM card not inserted or PIN enabled ON SIM status OK NET Green LED indicates C05 Network state OFF power off Blink once ON Low GSM signal ON SIM status OK Status Green LED ind...

Страница 9: ...with LPC 2 C05 module to the antenna connector 4 Mount other LPC 2 modules if required Mount each module to the DIN rail first then attach modules together through K1 and K2 connectors 5 Switch ON mai...

Страница 10: ...e code 04 year of code opening 001 derivation code 001 version code reserved for future HW and or SW firmware upgrades 3 D C 16 05 is the date code 16 week and 05 year of production Label 2 descriptio...

Страница 11: ...no flow control reserved for external AT commands Antenna connector SMA M Antenna impedance 50 Phone book capacity 100 SMS storage capacity 40 in ME mobile equipment up to 25 in SIM SIM dependent Freq...

Страница 12: ...6 BIT7 Range 0 1 Address MC3 0x1069 N 0x0040 MC7 0x0702 N 0x0040 Boolean variables Tx used to select the number of analogue BIT0 BIT3 and digital BIT4 BIT7 input signals I O Module FBOOL8 I O Name BIT...

Страница 13: ...I O Module FWORD16 I O Name WORD1 WORD2 WORD3 WORD4 WORD5 WORD6 WORD7 WORD8 Range 0 65535 Address MC3 0x143a N 0x0040 MC7 0x0103 N 0x0040 Boolean variable Tx used for alarming of the LPC 2 system s I...

Страница 14: ...he following table describes all the changes to the document Date V Description 1 7 2012 005 CGP General update New HW and FW version 11 5 2010 004 Updated warranty permanence 30 6 2005 003 The initia...

Страница 15: ...Longo programmable controller LPC 2 C05 6 NOTES 11...

Отзывы: