4 OPERATION
LPC-2.ID2V can be in one of two operational modes - normal or error. When LPC-2.ID2V is in normal
mode, module parameters can be read or written via Smarteh IDE software.
4.1 Operational modes
Normal
Communication with the main module is working. Only blue “PWR” LED6 is turned on.
Error
In case of communication fault, red “ERR” LED5 will turn on.
4.2 Parameters
If parameter is set to logical “1”, is considered to be active, enabled or set. If parameter has logical
value “0” is considered to be inactive, disabled or cleared.
Parameter can be a command or feedback. When parameter is marked as feedback it means that
LPC-2.ID2V is sending information to the main module. On the other hand, command represents
request from the main module to the LPC-2.ID2V.
Command:
Remote LED intesity
[oLdInts]
:
Command for setting LED intensity. Only valid while
oEnInts
active.
Type: WORD
Raw to engineering data:
0 .. 10000 0.00 .. 100.00%
→
ID Fault
[oFault]
:
Command for rejecting authorization of RFID code.
Type: BOOL
Raw to engineering data:
“0” Off
→
“1” RFID code rejected
→
ID OK
[oOk]
:
Command for accepting authorization of RFID code.
Type: BOOL
Raw to engineering data:
“0” Off
→
“1” RFID code accepted
→
Buzzer
[oBuzz]
:
While this command is active, buzzer is active.
Type: BOOL
Raw to engineering data:
“0” Buzzer off
→
“1” Buzzer on
→
En. Remote LED ints
[oEnInts]
:
Enables changing LED's intensity together with
oLdInts value.
Type: WORD
Raw to engineering data:
“0” Intensity changing disabled
→
“1” Intensity changing enabled
→
'Fault' ID LED
[oFaultLD]
:
While this command is active, fault LED2 is set.
Type: BOOL
Raw to engineering data:
“0” Fault LED2 off
→
“1” Fault LED2 on
→