background image

Copyright 1995 by SMART Devices Inc.

5945 Peachtree Corners East 

Norcross, GA 30071-1337

Table of Contents

SECTION 1

INTRODUCTION.........................................................................2

SECTION 2

SMART CTR2000 PHYSICAL DESCRIPTION ...........................2

SECTION 3

INSTALLATION ...........................................................................3

SECTION 4

OPERATION ...............................................................................3

SECTION 5

SYSTEM STATUS, PROGRAMMING & TEST MODES .............4

APPENDIX A

ILLUSTRATIONS FOR SETTING UP CTR2000.........................14

LIMITED WARRANTY:  SMART products and accessories are warranted against malfunction or failure due to defects in workmanship or
materials for a period of one year from the date of shipment. If a problem occurs during the warranty period, the unit will be repaired, or
replaced at our option, without charge for materials or labor.  If air freight is requested by the dealer, the difference between air and surface
charges will be billed to the dealer. This limited warranty does not cover products that have been abused, altered, modified, or operated in
other than specified conditions.  Prior factory approval is required on all returns.  Returned equipment or defective parts must be shipped
freight prepaid to us by the dealer or customer.

Our limited warranty does not cover damages resulting from accident, misuse or abuse, lack of responsible care, or failures not attributable to
manufacturing defects, except as provided herein.  SMART Devices, Inc. makes no warranties, express or implied, including warranties of
merchantability or fitness for a particular purpose.

RETURN POLICY:  Factory authorization MUST be obtained before returning any product.  A 15% restocking charge will be issued on unused
equipment (in original box) that is returned for credit. Credit is issued to the dealer’s account.  The credit may be used against future purchas-
es and no cash transactions are offered.  All returns must be shipped freight prepaid by the dealer.  Equipment returned without a factory RA
(Return Authorization) will be refused.

SMART products are designed to deliver unsurpassed quality in workmanship and
performance.  The following information gives detailed instructions on the installation
and operation of the SMART CTR2000.  We strongly encourage new owners of the
CTR2000 to thoroughly read this entire manual before placing their new SMART
product into service.  This will ensure that the CTR2000 will be operated properly to
give the superior performance that it was designed to deliver.

For service or installation assistance, please call our 

Technical Support Department between the hours of 

8 a.m-5 p.m. E.S.T., Mon.-Fri.

1-800-45-SMART

Содержание CTR-2000

Страница 1: ...dent misuse or abuse lack of responsible care or failures not attributable to manufacturing defects except as provided herein SMART Devices Inc makes no warranties express or implied including warrant...

Страница 2: ...ystem designed to operate with a variety of SMART Digital Audio Announcement Systems SMART CTR2000 when combined with a digital announcer services up to 8 incoming telephone lines The SMART CTR2000 co...

Страница 3: ...he first caller the convenience of hearing the message play from the beginning while additional callers enter the message in play Control mode requires a digital announcer capable of external start st...

Страница 4: ...c text presented on line 2 of the LCD Display When presenting a menu where the user selects a specific Function key Line 2 of the LCD is sectioned into 4 blocks where the first block of 5 characters i...

Страница 5: ...isplay Totalizes the number of calls received on each tele phone line Total Calls 999999 Press Clr To Exit press CLR 5 1 3 2 Per Line Call Count Menu The per line call count menu provides access to di...

Страница 6: ...5 seconds 5 2 1 2 Set Time and Date Enter Day tens digit Entering the day the system checks that the day entered is valid between 01 and 31 The tens digit must be between 0 3 Valid Keys 0 3 Clr Advanc...

Страница 7: ...ring the minutes the system checks that the min utes entered is valid between 00 and 59 The tens digit may be between 0 5 Valid Keys 0 5 Clr Advance to Second without making change To Exit Automatical...

Страница 8: ...me that a caller is allowed to remain on the line before the system will terminate the call The call hold time should be selected to allow the caller the opportunity to hear the complete message To Ex...

Страница 9: ...the morning The start and stop times should then be reviewed to ensure that they are the desired hours of operation To Exit Press CLR or automatically after 15 sec onds 5 2 2 5 Timed Programming Ever...

Страница 10: ...d between 00 and 12 The tens digit may only be a 0 or a 1 Valid Keys 0 1 To Exit Press CLR or automatically after 15 sec onds 5 2 2 9 2 Change Answer Start Time Enter Hour units digit Entering the hou...

Страница 11: ...s that the hour entered is valid between 00 and 12 The tens digit may only be a 0 or a 1 Valid Keys 0 1 To Exit Press CLR or automatically after 15 sec onds 5 2 2 10 2 Change Answer Stop Time Enter Ho...

Страница 12: ...ine 1 from T Timed to O Off press 1 To change line 1 to I On Idle press 1 again etc To Exit Press CLR or automatically after 15 sec onds 5 2 2 11 1 1 Change Line Configuration Monday Valid Keys 1 8 Co...

Страница 13: ...resulting in exiting the key pad test To Exit Press CLR 5 3 3 LCD Test The LCD Test is an alternating display where one line contains text and the only is solid black To Exit Press CLR 5 3 4 Nonvolati...

Страница 14: ...R2000 s to DASA300 Notes for both diagrams 1 All CTR2000 Control terminals require 8 pin din connectors 2 The Remote Start cable is an 8 pin din to 1 8 mini jack cable 3 The DASA300 MUST BE a looping...

Страница 15: ...15 INSTALLATION OPERATION Hookup of one CTR2000 to DASA300 DIAGRAM 1...

Страница 16: ...16 CTR2000 CONCENTRATOR Hookup for multiple CTR2000 s to DASA300 DIAGRAM 2...