26
RTM-ATCA-F125 Installation and Use (6806800K30J)
Hardware Preparation and Installation
Hardware Preparation and Installation
3. Remove the desiccant bag shipped together with the blade and dispose of it according
to your country’s legislation.
2.3
Environmental and Power Requirements
In order to meet the environmental requirements, the blade has to be tested in the system
in which it is to be installed.
Before you power up the blade, calculate the power needed according to your combination
of blade upgrades and accessories.
2.3.1
Environmental Requirements
The environmental conditions must be tested and proven in the shelf configuration used.
The conditions refer to the surrounding of the blade within the user environment.
The RTM is thoroughly inspected before shipment. If damage has occurred or items
missing during transportation, contact our customer's service immediately.
Remove the desiccant bag shipped together with the blade and dispose of it
according to your country’s legislation.
The environmental requirements of the blade may be further limited down due to
installed accessories, such as hard disks or PMC modules, with more restrictive
environmental requirements.
Operating temperatures refer to the temperature of the air circulating around the
blade and not to the actual component temperature.
NOTICE
Blade Damage–Blade Surface
Do not operate the blade outside the specified environmental limits. Make sure the
blade is completely dry and there is no moisture on any surface before applying
power.
Blade Overheating and Blade Damage
Operating the blade without forced air cooling may lead to blade overheating and
thus blade damage.
When operating the blade, make sure that forced air cooling is available in the shelf.
Содержание 6806800K30J
Страница 1: ...RTM ATCA F125 Installation and Use P N 6806800K30J November 2020...
Страница 6: ...List of Figures 6 RTM ATCA F125 Installation and Use 6806800K30J...
Страница 8: ...List of Tables 8 RTM ATCA F125 Installation and Use 6806800K30J...
Страница 24: ...24 RTM ATCA F125 Installation and Use 6806800K30J Introduction Introduction...
Страница 48: ...48 RTM ATCA F125 Installation and Use 6806800K30J Related Documentation Related Documentation...
Страница 49: ...1...