N O T E
On projectors with the RS-232 connector labeled
Control 9v
(rather than
Control
), pin 1 functions
as a +9V DC power source only for use with older model ECPs such as the ones shipped with
SMART UF55 projectors.
Serial interface settings
The serial interface of the projector acts as a Data Communications Equipment (DCE) device and its
settings can’t be configured. You must configure your computer’s serial communication program
(such as Microsoft HyperTerminal) or your room control system’s serial communication settings with
the following values:
Setting
Value
Data Rate
19.2 kbps
Data Bits
8
Parity
None
Stop Bits
1
Flow Control
None
N O T E S
l
Asynchronous mode is disabled by default in the projector.
l
All commands should be in ASCII format. Terminate all commands with a carriage return.
l
All responses from the projector are terminated with a command prompt. Wait until you
receive the command prompt indicating that the system is ready for another command before
you proceed.
l
The room control feature of the projector is always on.
g
To configure your computer’s serial interface
1. Turn on your computer, and then start your serial communications program or terminal
emulation program.
2. Connect your computer to the serial connection cable you previously connected to the ACP.
A P P E N D I X
B
Remotely managing your system through an RS-232 serial interface
84
Содержание SMART Board 800i5e-SMP
Страница 10: ......
Страница 24: ......
Страница 52: ......
Страница 60: ......
Страница 68: ......
Страница 84: ......
Страница 94: ......
Страница 110: ......
Страница 116: ...whiteboard See interactive whiteboard X XGA support 42 Z zoom 76 I N D E X 104...
Страница 117: ......
Страница 118: ...SMART Technologies smarttech com support smarttech com contactsupport...