background image

SOLID WHITE

Both Pebble and Base are on and ready.

GLOWING WHITE 

Pebble is in delayed start mode and will 

start listening for snoring in 30 minutes.

FLASHING BLUE 

Pebble and Base Bluetooth connection 

is broken. Make sure the Base and the 

Pebble are not connected with the USB 

cable; then, turn them both OFF. On 

the back of the Pebble, using the lock 

switch, “lock” the Pebble. Then, turn ON 

the Base first and connect USB Cable to 

the Pebble. Unlock the Pebble and turn 

it ON. Both the Base and the Pebble 

should now have a solid white light. If 

this does not solve your issue, please 

proceed to reset the Base and Pebble.

FLASHING RED

Pebble and/or Base are low on battery. 

Plug in the Base to power. Connect the 

Pebble to the Base using the USB cable. 

Charge both for at least 3 hours.

FLASHING GREEN

Pebble and Base are charging. The light 

will stop flashing once the battery is 

fully charged.  

To make sure this charging light does 

not interrupt your sleep, the green 

flashing light does not appear on top of 

the Pebble.

For additional support visit: 

PEBBLE & BASE LIGHTS

SUPPORT.SMARTNORA.COM

NON-MEDICAL DEVICE

Smart Nora is intended to rely on the 

detection of sounds consistent with 

snoring to slowly move the user’s  

pillow as an aid in reducing snoring. 

The device is indicated for those whose 

periodic snoring causes their partners to 

wake up. The device is not indicated for 

diagnosis or treatment of sleep apnea 

or any other condition or disorder. 

WARNINGS

 

Potential indicators of sleep disorder/

disease: Should any of the following 

symptoms or conditions co-exist with 

your snoring/sleeping difficulties, 

you should see your physician for an 

evaluation of obstructive sleep apnea.

1.  Frequent excessive daytime 

sleepiness.

2. Periods of not breathing, 

as observed by bed-partners.

3. Awaking short of breath, choking 

or gagging.

4. History of heart disease.

5. Substantially overweight.

 

CONTRAINDICATIONS

•  Smart Nora is not for use by  

infants or children.

•  Smart Nora is not for continued  

use if ineffective.

•  Smart Nora should not be used if it 

causes pain or other discomfort.

WARRANTY

Smart Nora Inc. offers a one-year 

manufacturer’s warranty. Warranty 

does not apply to damage caused by 

accident, abuse, misuse, flood, fire, 

earthquake, other external causes or 

use with improper power supply.

MAINTENANCE

The Pillow Insert and the felt bag cannot 

be washed or dry-cleaned. The Base 

and the Pebble contain electronics;  

to avoid damage, do not expose any  

of the parts to liquids, including water 

and cleaning products. The Pillow Insert 

may be cleaned using a damp cloth.

DISCLAIMER

REGISTER.SMARTNORA.COM

Activate your warranty at: 

24

  

SMART NORA USER MANUAL

24

23

Содержание Smart Nora

Страница 1: ...The Contact free Snoring Solution ...

Страница 2: ...ants and children 3 If your sleep habits and position put you at risk of entangling a cord or tube around your neck while sleeping do not use Smart Nora 4 Smart Nora is not a monitoring device and will not warn you of any sleeping problems 5 Avoid placing the power cable and air tube where it could present a tripping hazard 6 Do not use Smart Nora around water or other liquids Like any electronic ...

Страница 3: ...al bedroom environments During the night the Pebble a microphone equipped with detection algorithms listens for sounds of snoring Upon detecting multiple snores it activates the silent pump in the Base to gently inflate and deflate the Pillow Insert This slight movement interrupts your snoring After a few nights you will get used to this movement and notice Smart Nora less and less PEBBLE Micropho...

Страница 4: ...d insert sitting under your pillow This slight movement stimulates the relaxed throat muscles and as a result the airway assumes its natural position allowing you to breathe normally once again This movement lasts about 1 minute each time and during this time the device does not activate with sounds of snoring HAVE QUESTIONS WE RE HERE TO HELP SUPPORT SMARTNORA COM START SMARTNORA COM HOW SMART NO...

Страница 5: ...le Case under your bed 3 TURN BASE ON Press power button to turn on the Base 4 CONNECT PEBBLE Connect the Pebble to the Base with the USB cable NOTE The LED on the bottom of the Pebble flashes green when charging and stops flashing when the battery is full You can disconnect the Pebble when charging is complete 8 SMART NORA USER MANUAL 8 7 ...

Страница 6: ...use the Comfort Sleeve provided 7 PILLOW INSERT INFLATES As you speak or handle the Pebble the pump might activate If not press the Bluetooth button on the Pebble to test the inflation of the Pillow Insert NOTE If you see a blinking blue or red light see page 22 for troubleshooting 8 TEST BEFORE FIRST NIGHT Put your head on your pillow Press Bluetooth button You should feel a gentle rise and fall ...

Страница 7: ...rate velcro strips from the back of the mount Remove the liner off the adhesive strip 12 PLACE THE PEBBLE Place the Pebble inside of the mount This will help Smart Nora detect early sig nals of snoring regardless of the direction of your head 10 inches 10 PLACE THE PEBBLE Attach mount onto the vel cro strip until they click SETUP IS COMPLETE 12 SMART NORA USER MANUAL 12 11 ...

Страница 8: ... adjust the height setting to increase or decrease the movement of the pillow It s best to get used to Medium or High setting DAILY ROUTINE You can leave the Base plugged in and on Turn on the Pebble each night before bed Start the night with 30 minute Delay See page 17 10 INSTALL THE MOUNT Never pull the strips towards you or peel from the wall Always pull straight down 10 REMOVE THE MOUNT Remove...

Страница 9: ... the night with Delayed Start mode so you have 30 minutes to fall asleep before Smart Nora starts working See page 17 Nights 4 7 Your body will adjust to the movements and over time you will notice Smart Nora less and less Nights 7 Smart Nora will fade into the background and you might notice it occasionally Nights 1 3 As your partner becomes accustomed to using Smart Nora you will notice a reduct...

Страница 10: ...re on the pillow as long as the Pillow Insert moves your head when it rises and falls SET A 30 MINUTE DELAY To fall asleep easily start the night with Delayed Start To start the delay hold the on off button for 1 second White light on the Pebble will glow for 30 minutes Smart Nora will start working auto matically after 30 minutes To end the delay press the on off button 18 SMART NORA USER MANUAL ...

Страница 11: ...gnals of snoring regardless of the direction of your head 10 in PEBBLE PLACEMENT WRONG Do not place the Pebble further than 1 meter away If you must place on side table keep at the same level as your head Do not place the Pebble on a large table glass surface or vibrating surface Do not place the Pebble close to sources of noise such as a fan white noise machine or radio 1 m 20 SMART NORA USER MAN...

Страница 12: ...a A white blinking light appears on Pebble and Base and silent pump starts working PEBBLE FEATURES PILLOW HEIGHT ADJUSTMENT You can adjust the height of the inflated Pillow Insert For best results keep on high DC POWER Connect the power cable to keep the Base charged overnight USB PORT Connect the Pebble using the USB cable for charging If Bluetooth connection between Base and Pebble is broken Blu...

Страница 13: ...s an aid in reducing snoring The device is indicated for those whose periodic snoring causes their partners to wake up The device is not indicated for diagnosis or treatment of sleep apnea or any other condition or disorder WARNINGS Potential indicators of sleep disorder disease Should any of the following symptoms or conditions co exist with your snoring sleeping difficulties you should see your ...

Страница 14: ...pproval Complied All EU countries Switzerland and Norway INDUSTRY CANADA This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference includ ing interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR ...

Страница 15: ...WWW SMARTNORA COM ...

Отзывы: