4.4.3.

 

Replacing the Battery 

If the shelf life of battery is end, contact us and purchase the battery part.

It  provides  the  other  information  such  as  circuit  diagrams,  par ts  and
description  that  is  needed  to  repair  the  product  when  the  ser vice
personnel are required.

Tel: +82-70-7525-2104 E-Mail: 

[email protected]

Homepage: 

http://www.smd21.com

WARNING

 

Only the trained service personnel of the manufacturer will carry out the repair service.

Do not disassemble or modify the equipment including internal parts without written

consent  from  the  manufacturer.  This  may  cause  electric  shock  or  injury,  product
malfunction, inaccurate results, and will void the 

manufacturer’s warranty.

The minimum qualifications for SERVICE PERSONNEL.

- Service and Installation trained service personnel.

-

Only personnel read the instruction manual or received training to use.

4.4.4.

 

Expected service life 

The Dr.MUSIC 3s has an expected service life of 3 years. To maintain the condition of the 

device have the device maintained regularly according to the schedule recommended by 

manufacturer.

 

4.4.5.

 

Disposal 

The device described  in this manual  must be disposed of in  compliance 

with  the  applicable  local  waste  control  regulations  at  the  end  of  their 
service  life.  If  you  have  questions  regarding  the  disposal  of  the  device, 

please contact the manufacturer or an authorized disposal company. 

Содержание DM-VME03S

Страница 1: ...1173 Website Http www smd21 com E mail sales smd21 com 2016 SmartMedicalDevice Co Ltd All rights reserved Reproduction in whole or in part in any form or by any means electrical mechanical or otherwi...

Страница 2: ...roved All references to standards regulations and their revisions are valid for the time of publication of this instruction for use The screen graphics and illustrations in this manual are for illustr...

Страница 3: ...inst vertically falling water drops when tilted up to 15 degrees IEC60529 Manufacturer information This symbol is followed by the name and address of the device manufacturer ISO 15223 1 2012 Manufactu...

Страница 4: ...ext to the battery indicator Bluetooth This device conforms to the following international standards IEC 60601 1 2012 Electrical medical equipment IEC 60601 1 2 2014 Electromagnetic compatibility IEC...

Страница 5: ...DR MUSIC 3S APP 15 3 OPERATING THE DR MUSIC 3S 17 3 1 PRECAUTIONS BEFORE USING 17 3 2 USING THE DEVICE ALONE 20 3 3 USING THE DEVICE WITH MOBILE APP 23 3 4 CHARGING THE DEVICE 32 4 MAINTENANCE AND IN...

Страница 6: ...Dr MUSIC 3s Model DM VME03S SMD IFUE DMV 001 Rev 0 6 1 1 Contraindications 1 2 General safety Chapter 1 Safety Information...

Страница 7: ...woman or people with the possibility of pregnancy You have cardiac disorder and cardiac lesion You are physically and mentally debilitating You have a problem for a blood pressure People with high bod...

Страница 8: ...tion People who want to use this device as a part of rehabilitation People who received medical treatment by doctor People with serious illnesses what damage has not been mentioned in this document 1...

Страница 9: ...presence of electronic monitoring devices heart monitor ECG alarms etc Patients that are connected to the high frequency surgery equipment is prohibited to use Skin may cause burns and the device may...

Страница 10: ...odel DM VME03S SMD IFUE DMV 001 Rev 0 10 2 1 Dr MUSIC 3s 2 1 Operating principle 2 2 Intended use 2 3 Product Components 2 4 Exterior and Function 2 5 Layout of Dr MUSIC 3s APP Chapter 2 Dr MUSIC 3s I...

Страница 11: ...tended to be used by adults for temporary relief of pain associated with sore aching muscles in the shoulder waist back neck upper extremities arm and lower extremities leg due to strain from exercise...

Страница 12: ...d active implantable medical devices e g Implanted pace maker Do not use on infants or patient who cannot properly expresses Refer to Chapter 1 1 Contraindications in this user s manual Nationality Mu...

Страница 13: ...evel Output Orange LED Battery Blue LED Intensity Button Control of the level 0 to 11 grades 12 to 23 grades 24 to 35 grades Battery Indicator Indicated the Status of the battery charging Charging Ora...

Страница 14: ...the higher intensity the LED is lighting from left to right gradually output indicator Each of LED is flashing during output Music sync Tapping Massaging Low battery indicator When battery is low LED...

Страница 15: ...tle and status icons Connect control Control the connection to the device Output intensity control Control and display the output intensity of the stimulation Contents area Change the operation mode D...

Страница 16: ...MUSIC 3s Model DM VME03S SMD IFUE DMV 001 Rev 0 16 3 1 Precautions before using 3 2 Using the device alone 3 3 Using the device with Mobile APP 3 4 Charging the device Chapter 3 Operating the Dr MUSIC...

Страница 17: ...he skin Make sure that skin you want to place the electrodes on looks healthy and is free from wounds or rashes The skin you want to place the electrodes on must be dry clean and free from cream or lo...

Страница 18: ...he electrodes are not properly attached to the skin it may not be able to operate the device If the electrodes are not properly attached to the skin current flow is concentrated can cause burns If the...

Страница 19: ...strong electrical shock to the body To move the electrode during use in other parts of the body you must first turn off the power of the product Depending on the strength It will be may result in a s...

Страница 20: ...ble Connector from the micro USB socket 2 Connect the electrodes with electrode connector 3 Place the electrodes on the part at the place you want to treat such as shoulder leg arm etc 4 Long press th...

Страница 21: ...he orange LED is lighting at each position of selected mode 6 After selecting mode use by adjusting the intensity of low frequency stimulus using intensity button a The operation time is 20 minutes b...

Страница 22: ...8 Long press the Power Mode Button of device If you do not operate within 5minutes the device switches off automatically 9 Pull the electrodes to detach from skin 10 Separate the electrodes from devi...

Страница 23: ...v 0 23 3 3 Using the device with Mobile APP 3 3 1 APP Download Install the Android APP 1 Check whether supported device or not Android 4 3 2 RuntheAPPstore 3 Press the search 4 Type the Dr MUSIC3 in s...

Страница 24: ...del DM VME03S SMD IFUE DMV 001 Rev 0 24 Install the iOS APP 1 Check whether supported device or not iOS 7 2 RuntheAPPstore 3 Press the search 4 Type the Dr MUSIC3 in search 5 Install the APP 6 Run the...

Страница 25: ...from the micro USB socket 2 Connect the electrodes with electrode connector 3 Place the electrodes on the part at the place you want to treat such as shoulder leg arm etc 4 Long press the Power Mode B...

Страница 26: ...ch the Dr MUSIC 3s at list 9 Activate the mode You can select the mode among Music Sync Mode Tapping Mode and Massaging Mode Music Sync Mode Touch the Music Sync mode button After touching the Music l...

Страница 27: ...gain you touch the start button Touch the TIME button to setting the operation time Setting time 5 to 30 min Basic Setting time 20 min Tapping Mode Touch the Tapping mode button After touching the Tap...

Страница 28: ...n you touch the start button Touch the TIME button to setting the operation time Setting time 5 to 30 min Basic Setting time 20 min Massaging Mode Touch the Massaging mode button After touching the Ma...

Страница 29: ...20min Using the device with mobile APP Total Music Sync 1 100Hz 50 150 s 20min Total Tapping 2 10Hz 50 s 20min Intensive tapping 2Hz 10Hz 50 s 20min Smooth tapping 3Hz 5Hz 50 s 20min Wave tapping 2 10...

Страница 30: ...FUE DMV 001 Rev 0 30 Setting 1 Touch the Setting button at top right 2 Check the Basic information APP Information Send e mail User s Guide 3 Set the save record Record store presence The time range u...

Страница 31: ...APP quit at mobile phone 2 Long press the Power Mode Button of device 3 Pull the electrodes to detach from skin 4 Separate the electrodes from device 5 Stored electrodes by attaching on the holder to...

Страница 32: ...device is stored during prolonged Keep state of battery from 40 to 60 after removing control part Do not store in the car that is exposed to direct sunlight When the battery part of device become infl...

Страница 33: ...et 2 Insert the charging cable into the micro USB socket of the device 3 The battery indicator is solid orange during charging 4 When the battery is fully charged the battery indicator turns solid gre...

Страница 34: ...ation of Dr MUSIC 3s 4 2 Specification of External Device connection 4 3 Questions about Equipment 4 4 Maintenance 4 5 EMC Electro Magnetic Compatibility 4 6 FCC Federal Communications Commission 4 7...

Страница 35: ...stage is from 0 to 35 Whenever increases the output intensity by one The output voltage is increased 1Vpk Starting from 4Vpk at Stage 1 finally maximum output voltage is 38Vpk at 35 stages Rated load...

Страница 36: ...e Mobile APP interface Data format Bluetooth Device status information Read Channel Notify Channel 0000fff4 Device information Bringing information when connecting to BLE Battery information Receiving...

Страница 37: ...data Therefore in the case of virus infection it should be operated by an antivirus program Specification of Network connection Communication protocol The protocol between the main unit and the mobil...

Страница 38: ...Dr MUSIC 3s to an IT Network that includes other equipment could result in previously unidentified risks to patient operator or third parties 3 The users should identify analyze evaluate and control...

Страница 39: ...the mode A2 If the electrodes are not properly attached you will be felt different or less pleasant than usual Check if the electrodes are attached to the skin properly A3 The electrodes are worn Rep...

Страница 40: ...e surface Storage the product specified environment cited under chapter 4 1 Specification of Dr MUSIC 3s WARNING Always operate this product within prescribed ranges of temperature humidity and pressu...

Страница 41: ...his may cause electric shock or injury product malfunction inaccurate results and will void the manufacturer s warranty The minimum qualifications for SERVICE PERSONNEL Service and Installation traine...

Страница 42: ...emissions IEC 61000 3 3 Complies Guidance and Manufacturer s Declaration Electromagnetic Immunity This device is intended for use in the electromagnetic environment specified below The user of this d...

Страница 43: ...ce and Manufacturer s Declaration Electromagnetic Immunity This device is intended for use in the electromagnetic environment specified below The user of this device should make sure it is used in suc...

Страница 44: ...e less than 3 V m Recommended Separation Distances between Portable and Mobile RF Communications Equipment and This Device The device is intended for use in an electromagnetic environment in which rad...

Страница 45: ...d to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipmen...

Страница 46: ...DM VME03S SMD IFUE DMV 001 Rev 0 46 4 7 Marking plate Trademark Dr MUSIC 3s Model DM VME03S Position of label the back side of Control part Label of device Position of box label the bottom side of ou...

Отзывы: