background image

1 Box contents

Make sure you receive all items of your shipment:

One PrAMC-7311

One printed copy of Quick Start Guide (this document)

One printed copy of Safety Notes Summary

When installing or servicing the system or accessories, 
strictly observe the safety precautions in the 

Safety Notes 

Summary

. Ignoring these instructions can void the system 

warranty and cause personal injury or property damage.

2 ESD

Electrostatic discharge and incorrect installation or 
removal of the card can damage circuit or shorten its life.

Use a properly grounded ESD wrist strap or work in an 
ESD-safe environment. 

Connect to the ESD connector at the front or the rear of 
the system.

3 Site preparation

Make sure that all environmental and power requirements 
defined in the 

PrAMC-7311Installation and Use

 manual 

are met.

Operating temperatures refer to the temperature of the air 
circulating around the blade and not to the actual 
component temperature.

For more information about connecting cables and power cords, 
refer to the 

PrAMC-7311 Installation and Use 

manual.

4 Install the PrAMC-7311

The following procedure assumes that your system is powered. If 
your system is unpowered, you can disregard the blue LED and skip 
the respective step.

1. Identify the AMC bay to be used for the installation.

2. If the required AMC bay is occupied by an AMC filler panel, you 

will need to remove the filler panel before proceeding with the 
installation procedure.

The removal procedure for the filler panel is the same as 
described in the Removal procedure which follows immediately 
after this procedure. Ignore steps that mention the blue LED.

3. Make sure that the AMC module handle is in the extracted 

position, pulled outward, away from the face plate.

4. Using your thumb, apply equal and steady pressure on the face 

plate as necessary to carefully slide the AMC module into the 
guides rails.

5. Continue to gently push the module along the guide rails till the 

module is fully engaged with the connector. Avoid using 

excessive force during this operation

.

6. Wait for the blue LED to glow. The blue LED glows when the 

AMC module is completely engaged with the connector.

7. Press module handle inwards toward the face plate to lock the 

AMC module on AMC bay.

8. Wait for the blue LED to perform a series of long blinks. The blue 

LED blinks when the handle is locked in position indicating 
module detection and activation by the carrier board.

9. Observe blue LED status/activity. The module is fully installed 

when the blue LED stops blinking and stays OFF.

5 Remove the PrAMC-7311

1. Remove any cables that are connected to the AMC module 

face plate connectors.

2. Gently pull the module latch outward, approximately 3 mm from 

its locked position.

3. Wait for the blue LED to first perform short blinks, and then glow 

persistently.

4. Once the blue LED glows persistently, gently pull the AMC 

module handle outward to disconnect the module from the AMC 
connectors.

5. Continue to gently slide the module outward along the guide 

rails.

PrAMC-7311