background image

C. Chapman 

Page 1 

SNX Top Channel 4.11.2004 V1.0 

 

 

Ranmore Manor, Ranmore Common, Dorking, Surrey, RH5 6SX 

Tel: +44 (0)1483 283 365  Fax: +44 (0)1483 281 511 

 

Procedure for setting SmartNet X Top Channel 

 

The Top Channel feature allows users to specify the uppermost source/input. 

 

There are two methods of setting up this feature. 

 

Manual. 

(

You will need to be able to see the Yellow LED on the front of the SmartNet) 

 

Equipment List 

You will need the following list of equipment; 

 

¾

 

1 x Classic Smart 4 Infrared handset. 

¾

 

1 x UTP Patch Cable. 

¾

 

1 x SLX-RX200. 

¾

 

1 x SM-EYE Infrared Eye. 

¾

 

1 x SmartNet X to be configured. 

 

Procedure 
1.

 

Connect the equipment listed above as shown in the diagram below. 

 

 

 

 

2.

 

Power down the SmartNet hub. 

3.

 

Make a note of the setting on the rotary switch on the right hand side of the front of the 
SmartNet unit. 

4.

 

Set the rotary switch so that the arrowhead points to position F. 

5.

 

Re-power the SmartNet hub.  The Yellow LED will Blink 4 times and stop. 

Отзывы: