A P P E N D I X B
Remotely managing your system through an RS-232 serial interface
86
Field
Possible Values
Description
target testpattern
l
= ?
Set the test pattern to pattern number X (1~4).
If only one test pattern, call it test pattern 1.
current testpattern
l
1: Grid
l
2: RED
l
3: Green
l
4: Blue
l
5: Grey
l
6: Black
Current test pattern being displayed. Just
return the test pattern number is OK. The built-
in test pattern may be changed.
target colorwheelidx
l
= ???
The ranges must match the OSD ranges
current colorwheelidx
l
???
The ranges must match the OSD ranges
current failurelog
l
normal
l
overtemp
l
fanlock
l
fanDMD
l
fanblower
l
fansystem
l
lamperror
l
colorwheelbreak
l
lampignite
l
lampoverheat
l
lampdriver
l
lampoverhours
Current error state that the projector is in. The
modes are projector dependent.
Current error#
Provide the details of
the specific error. ‘#’ is
the number recorded
in the log. It ranges
from 1 to 5. 1
indicates the most
recent error and 5
indicates the oldest
error.
The details include the failure reason, system
hours, lamp hours, sensor temperature and
lamp voltage. For example: error1=fansystem,
syshrs:1000, lamphrs=1000, temp=60,
volt=120. error2=lampoverheat, syshrs:3000,
lamphrs=2900, temp=150,volt=120.
target factoryreset
l
= true
l
= false
If set to true, perform a factor reset. Otherwise
do nothing.
current factoryreset
l
= true
l
= false
Set to true only if a factor reset is about to
occur.
target highspeedfan
l
= high
l
= normal
The ranges must match the OSD ranges
Содержание Board 600i6
Страница 1: ...SMART Board 600i6 Interactive whiteboard system Configuration and user s guide...
Страница 2: ......
Страница 13: ......
Страница 19: ......
Страница 39: ......
Страница 47: ......
Страница 55: ......
Страница 105: ......
Страница 109: ......
Страница 111: ......
Страница 115: ......
Страница 116: ......
Страница 117: ...SMART Technologies smarttech com support smarttech com contactsupport...