Appendix D
Managing SMART Board 6000S (C) or 6000S series displays using RS-232
94
Power state
Description
STANDBY
The screen is off, and the display is in a low power state. The display enters READY
or ON state when one of the following occurs:
l
The proximity sensors detect people in the room.
l
A user presses the
Power
button
on the convenience panel or the remote
control.
l
You send the
set powerstate=ready
or
set powerstate=on
command.
This power state is the default energy saving mode for displays set to a non-EU
location.
NOTE
The EU uses “networked standby” to describe this power state.
POWERSAVE
The screen is off, and the display is a very low power state. The display enters
READY or ON state when one of the following occurs:
l
A user presses the
Power
button
on the convenience panel or the remote
control.
l
You send the
set powerstate=ready
or
set powerstate=on
command.
This power state is the default energy saving mode for displays set to an EU location.
NOTE
The EU uses “standby” to describe this power state.
UPDATEON
The display is updating firmware. Do not turn off the display.
UPDATEREADY
The display is updating firmware while the screen is off. Do not turn off the display.
With the exception of
get powerstate
and
set powerstate
, commands are available only when the