PCI-5000
Series Multifunctional Data
Acquisition Devices
User Manual
Rev. A
Beijing Smacq Technology Co., Ltd.
Smacq.com
Smacq.cn
Страница 1: ...PCI 5000 Series Multifunctional Data Acquisition Devices User Manual Rev A Beijing Smacq Technology Co Ltd Smacq com Smacq cn...
Страница 2: ...ied for this document as well as the information inside it including but not limited to implied warranties of the marketable nature of the product and its suitability for a particular purpose There ma...
Страница 3: ...evice damage the internal security protection mechanism will also be affected Warning Do not attempt to replace device components or change devices in other ways that are not mentioned in this documen...
Страница 4: ...ordability of the device Measurement categories II CAT II means that measurements are made on a circuit that is directly connected to a low voltage device For example a measurement on household applia...
Страница 5: ...orage 5 RH 95 RH no condensation Pollution degree 2 Highest elevation 2000 m Pollution degree description Pollution degree 1 No pollution or only dry non conductive pollution This pollution degree has...
Страница 6: ...Signal acquisition mode 20 Continuous acquisition mode 20 Limited number acquisition mode 20 Single point reading 21 3 3 Sampling rate 21 3 4 Trigger 21 Clear trigger 21 4 Digital Input DI 22 4 1 Sig...
Страница 7: ...6 6 1 Synchronous clock 26 6 2 External trigger input 26 6 3 trigger output 26 7 Service and Warranty 28 8 Ordering Information 29...
Страница 8: ...als continuously and save the data to the computer hard drive without interruption It can also provide digital signal output periodic repetitive signal output PCI 5000 series data acquisition device s...
Страница 9: ...lock source AI Digital I O FIFO cache Figure 1 1 PCI 5000 series data acquisition device functions 1 3 Product specifications The following product specification parameters unless otherwise stated are...
Страница 10: ...und voltage of each input side does not exceed 12 V Software FIFO 2 MPts Ch Onboard FIFO 4096 Pts shared AI capture mode Continuous acquisition mode Limited collection mode Single read Analog input ac...
Страница 11: ...Channel synchronization Yes Software FIFO 2MPts Onboard FIFO 4096 Pts shared Digital input acquisition mode Continuous acquisition Limited collection Single read Digital output mode Direct output fini...
Страница 12: ...ing to the grounded object Do not touch the exposed pins of the connector Place your device in anti static packaging when you are not using the device Check the packing list After unpacking the produc...
Страница 13: ...synchronization interface 2 Installation This chapter describes signal connection and drive installation of PCI 5000 series data acquisition device 2 1 Connector signal pins distribution Figure 2 1 PC...
Страница 14: ...on Signal name Notes AI 0 Analog input 0 AI 1 Analog input 1 AI 2 Analog input 2 AI 3 Analog input 3 AI 4 Analog input 4 19 AI 0 18 AI 1 17 AI 2 16 AI 3 15 AI 4 14 AI 5 13 AI 6 12 AI 7 11 GND 10 GND 9...
Страница 15: ...tallation PCI 5xxx data acquisition device can be used in Windows 7 and Windows 10 including 32 bit and 64 bit Here taking the driver installation in Windows 10 environment as an example we will intro...
Страница 16: ...15 Figure 2 4 Before the driver is installed...
Страница 17: ...re and Signal Processing Controller right click and select Update Driver Select Browse my computer to find driver software in the pop up dialog box as shown in Figure 2 5below Figure 2 5 Browse my com...
Страница 18: ...the pop up dialog box click Browse button locate the operating system version folder corresponding to the driver and then click Next as shown in Figure 2 6 Figure 2 6 Locate the folder where the drive...
Страница 19: ...starts to enter the driver installation process After the installation is successful the dialog box shown in Figure 2 6 below pops up and the driver installation is completed Figure 2 7 Driver install...
Страница 20: ...19 Figure 2 8 Device Manager after successful driver installation...
Страница 21: ...des Continuous acquisition mode Limited collection mode Single read The sampling rate of the first two modes adopts hardware timing The limited number acquisition mode is called OneShot mode Continuou...
Страница 22: ...ce provides rich trigger options The schematic diagram of the AI acquisition trigger options are shown in Figure 3 1 AiSoftTrig software trigger DiSoftTrig software trigger DoSoftTrig software trigger...
Страница 23: ...eed buffers it in the FIFO and continuously uploads the data in the FIFO to the computer memory buffer The user program only needs to continuously process the data in memory to achieve continuous unin...
Страница 24: ...r signal Figure 4 1 DI trigger options The DI acquisition uses the DiSoftTrig software trigger as the trigger source by default The DI acquisition can use other trigger sources via software settings t...
Страница 25: ...s greater than 0 AO works in the limited output mode Immediate output Immediate output refers to the output state without buffer and no waveform The computer sends a command to the acquisition device...
Страница 26: ...2 Output update rate PCI 5000 series data acquisition device DO output update rate can reach up to 10MSa s Ch 5 3 Trigger The PCI 5000 series of data acquisition devices provide a rich set of trigger...
Страница 27: ...re and the default setting for power on is input The circuit diagram of the synchronous clock port is shown in Figure 6 1 Figure 6 1 The circuit diagram of the synchronous clock port 6 2 External trig...
Страница 28: ...oftTrig software trigger AoSoftTrig_0 software trigger AoSoftTrig_1 software trigger DoSoftTrig software trigger Globa software trigger Trig_IN external trigger DO trigger signal Figure 6 2 Schematic...
Страница 29: ...to the warranties mentioned in this manual and the warranty note we do not provide any other warranties express or implied including but not limited to any implied warranties as to the tradable natur...
Страница 30: ...211 8 AI 500kS s Ch 6 DIO Optional accessories Model Notes DB37CB 1 5M DB37 connecting line double male 1 5m DB37TB End board DIN guide rail installation CHF 100B Current sensor 100A DC 20kHz output 4...