5.2 Scope of delivery STORAGE-67-TS-10
ITEM
QUANTITY DESCRIPTION
1
1
Battery cabinet
TS HV
1 .1
4
L
Crane lifting eye
pre-fitted
1 .2
2
L
Crane bracket
pre-fitted
1 .3
1
L
C-rail
pre-fitted
1 .4
2
L
Document pouch
pre-fitted
1 .5
2
L
Comb busbar
pre-fitted
2
1
SMA HV APU
(APU HV1000-S)
3
14 or 16
Battery module HV1000
(battery module 4.8 - 1C - HV 1000) incl. Active Battery Optimizer (ABO)
4
1
APU connector set
HV1000
from the APU to the first and last (14th/16th) battery module
4 .1
1
L
DC connecting cable
950 mm, 35 mm² (red on red)
4 .2
1
L
DC connecting cable
1150 mm, 35 mm² (black on black)
4 .3
1
L
Patch cable
CAT 6, 300 mm
4 .4
1
L
APU ground
700 mm, 16 mm², green-yellow, M 6 - M 8
5
1
Module connector set HV1000
(for 16 battery modules, extra pack each with 2 additional cables)
5 .1
12
L
DC connecting cable
550 mm, 35 mm
2
(red on black)
5 .2
12
L
Patch cable
CAT6, 300 mm
5 .3
12
L
Rack balancing cable
240 mm
6
1
Cabinet connector set HV1000
6 .1
1
L
DC connecting cable
1,200 mm, 35 mm
2
(red on black)
6 .2
1
L
Patch cable
CAT 6, 1,000 mm
6 .3
1
L
Rack balancing cable
1,100 mm
7
1
DC connector set HV1000
APU to battery inverter/BatBreaker
7 .1
1
L
DC connecting cable
5,000 mm, 35 mm
2,
with red plug on one side
7 .2
1
L
DC connecting cable
5,000 mm, 35 mm
2,
with black plug on one side
7 .3
2
L
Wire end ferrules
35 mm² insulated
7 .4
1
L
Patch cable
CAT6, 5,000 mm
7 .5
1
L
Ground cable
5,000 mm, 16 mm
2
, M 8 ring terminal
8
2
Switch
Netgear GS 308
9
2
Rack balancing cable
750 mm
10
3
Type plate STORAGE-67-TS-10
11
1
Cabinet accessories
11 .1
8
L
screw M12 x 25
for the optional lifting of the cabinet cover
11 .2
4
L
Plastic washer
for M12 screw for the optional lifting of the cabinet cover
11 .3
8
L
Spacer M12
for the optional lifting of the cabinet cover
11 .4
100
L
Pan head screw M6 x 16 Tx with washer
11 .5
2
L
Cable retention clip for strain relief
for mounting on C-rail
12
1
SMA Inverter Manager
13
1
CLCON power supply
14
1
Janitza network analyzer UMG 604E-Pro
15
optional
BatBreaker
optional, included in scope of delivery for master/slave systems
16
optional
DC connector set BatBreaker for the Bat-INV (battery inverter) HV1000
2x 1000
mm, 35 mm
2
17
1
Installation and Operating Manual STORAGE-67-TS-10
18
1
TESVOLT USB drive
19
1
Battery chamber sticker