8 Technical Data
General Data
Mounting location
In the inverter
Voltage supply
Via the inverter
Mechanical data
Width x height x depth
60 mm x 105 mm x 33 mm
Ambient conditions for storage/transport
Ambient temperature
-40°C to +70°C
Relative humidity, non-condensing
4% to 100%
Maximum height above mean sea level
3000 m
Ambient conditions during operation
Ambient temperature
-40°C to +85°C
Relative humidity, non-condensing
4% to 100%
Maximum height above mean sea level
3000 m
Temperature inputs
Quantity
2
Measuring shunt
Platinum sensor Pt100, platinum sensor Pt1000
Type of measurement
Two-conductor connection technology, four-
conductor connection technology
Measurement range
-40°C to +85°C
Typical measurement accuracy
±0.3°C when measured with four-conductor
connection technology
Maximum measurement error
±1.7°C when measured with four-conductor
connection technology
Maximum cable length
20 m when measured with four-conductor
connection technology
2.5 m when measured with two-conductor
connection technology
Analog input / current or voltage input
Quantity
1
Measurement range of the voltage input
0 V to 10 V
8 Technical Data
SMA Solar Technology AG
Installation Manual
MDSEN-40-IA-en-10
28