1
Страница 1: ...1...
Страница 2: ...cy better than 20 ns For indoor installations timing accuracy is better than 500 ns Device specifications are provided in Table 1 Table 1 JT DO1 specifications Physical Dimensions 4 62 in x 2 12 in x...
Страница 3: ...1 0 in The chassis is drilled with four 0 2 in mounting holes two on each flange The flange mounting holes are separated by 1 0 in An additional mounting slot is provided between the mounting holes o...
Страница 4: ...a paperclip or similar probe The rear panel provides power and serial connections through keyed pluggable Phoenix screw terminals The mating connectors for both the power and serial connections on the...
Страница 5: ...ctronics The acceptable operating temperature range of the JT DO1 timecode generator is from 20 C to 75 C Operation The JT DO1 is powered from a DC source with acceptable input voltage range from 4 5...
Страница 6: ...current consumption of the device is 160 mA If the IRIG B and PPS outputs are connected to high impedance loads or are disconnected the typical current consumption is 60 mA Time date and status inform...