10. Power Management
10.1 Power Management Features
A number of unused functions can be powered down to minimize power consumption. The registers listed in the table below are used
for powering down different features of the device.
Table 10.1. Powerdown Registers
Register Name
Hex Address [Bit Field]
Function
PDN
0x001E[0]
Place the device into a low current Power-
down state. Note that the serial interface
and registers remain active in this state.
0: Normal Operation (default)
1: Powerdown Device
OUT0A_PDN
OUT0_PDN
OUT1_PDN
OUT2_PDN
OUT3_PDN
OUT4_PDN
OUT5_PDN
OUT6_PDN
OUT7_PDN
OUT8_PDN
OUT9_PDN
OUT9A_PDN
0x0103[0]
0x0108[0]
0x010D[0]
0x0112[0]
0x0117[0]
0x011C[0]
0x0121[0]
0x0126[0]
0x012B[0]
0x0130[0]
0x0135[0]
0x013A[0]
Powers down unused output drivers.
0: Power-up output driver (default)
1: Powerdown output driver
When powered down, output pins will be
high impedance with a light pull down ef-
fect.
OUT_PDN_ALL
0x0145[0]
Powers down all output drivers.
0: Normal Operation (default)
1: Powerdown All output drivers
IN_EN
0x0949[3:0]
Enable (or powerdown) the IN3 - IN0 input
buffers.
0: Powerdown input buffer
1: Enable and Power-up input buffer
10.2 Power Supply Recommendations
Power supply filtering is generally important for optimal timing performance. The Si5386 devices have multiple stages of on-chip
regulation to minimize the impact of board level noise on clock jitter. Following conventional power supply filtering and layout techniques
will minimize signal degradation from power supply noise.
It is recommended to use a 0402-size 1 μF ceramic capacitor on each power supply pin for optimal performance. If the supply voltage is
extremely noisy, it might require a ferrite bead in series between the voltage supply voltage and the device power supply pin.
Si5386 Rev. E Reference Manual • Power Management
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
73
Rev. 1.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • December 9, 2021
73