Table 5.10. Jitter Performance Specifications
(V
DD
= V
DDA
= V
DD_DIG
= V
DD_XTAL
= 1.8 V to 3.3 V +10%/-5%, V
DDO
= 1.8 V ±5%, 2.5 V ±5%, or 3.3 V ±5%, T
A
= –40 to 85 °C)
Parameter
Symbol
Test Condition
Typ
Max
Units
Jitter Generation,
Locked to External 25 MHz
Clock
J
GEN
INT Mode
12 kHz – 20 MHz
210
280
fs RMS
FRAC/DCO Mode
12 kHz – 20 MHz
250
fs RMS
J
PER
Derived from integrated phase noise at a
BER of 1e-12
3.3
ps Pk-Pk
J
CC
3.1
ps Pk
J
PER
N = 10, 000 cycles Integer or Fractional
Mode.
Measured in the time domain.
Performance is limited by the noise floor of
the equipment.
12
ps Pk-Pk
J
CC
11
ps Pk
Jitter Generation,
Locked to External 25 MHz
Crystal
J
GEN
INT Mode
12 kHz – 20 MHz
190
240
fs RMS
FRAC/DCO Mode
12 kHz – 20 MHz
250
fs RMS
J
PER
Derived from integrated phase noise at a
BER of 1e-12
3.5
ps Pk-Pk
J
CC
3.1
ps Pk
J
PER
N = 10, 000 cycles Integer or Fractional
Mode.
Measured in the time domain.
Performance is limited by the noise floor of
the equipment.
12
ps Pk-Pk
J
CC
11
ps Pk
Jitter Generation,
Locked to Embedded 50 MHz
Crystal
J
GEN
INT Mode
12 kHz – 20 MHz
175
215
fs RMS
FRAC/DCO Mode
12 kHz – 20 MHz
250
fs RMS
J
PER
Derived from integrated phase noise at a
BER of 1e-1
3.2
ps Pk-Pk
J
CC
2.8
ps Pk
J
PER
N = 10, 000 cycles Integer or Fractional
Mode.
Measured in the time domain.
Performance is limited by the noise floor of
the equipment.
12
ps Pk-Pk
J
CC
11
ps Pk
Power Supply Noise Rejection
PSNR
25 kHz
–100
—
dB
50 kHz
–97
—
100 kHz
–72
—
500 kHz
–83
—
1 MHz
-91
—
Si5332 Data Sheet • Electrical Specifications
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
30
Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 16, 2021
30