E_MH_Mounting_instructions_Skylux_Climaglide_10mm_carrier_system
10/09/2021
CLIMAGLIDE IS A REGISTERED BRAND OF SKYLUX
SPINNERIJSTRAAT 100 - B-8530 STASEGEM
T +32 (0)56 20 00 00 - F +32 (0)56 21 95 99
WWW.SKYLUX.BE
ONLY USE ORIGINAL PARTS DELIVERED BY SKYLUX. EVERY GUARANTEE IS CANCELLED IF NON-ORIGINAL PARTS ARE USED.
THESE GUIDELINES ONLY HAVE AN ADVISORY CHARACTER. ASSEMBLY FALLS UNDER THE ENTIRE RESPONSIBILITY OF THE CUSTOMER.
The finish
Install the locking block on the parking side on the lower rail with a hex key. Adjust the position so that the lock
enters the opening of the carrier profile.
Also test the locking positions of the other sliding elements.
For the seal against rainwater, we recommend finishing the lower rail on the inside with silicone.
You can additionally opt for round handles. We offer two different types:
- to be glued to the glass panels (glass glue can be ordered separately)
- to screw into the glass panels (predrill the glass panels with Ø 60)
To prevent someone walking into the transparent sliding elements, we recommend affixing a self-adhesive opaque
strip to the glass at eye level.
If you have ordered the sealing brushes, they can now be sawn to length and be fixed on the glass with a suitable
glue (TEC7 transparent or simular).