Mid Size & Full Size RT’s
Engine Powered
February 2008
SKYJACK, Page 23
Component Identification (Special Options)
Section 2 - Operation
2.6-3 1500W AC Inverter (If Equipped)
The inverter is located on the base of the aerial platform.
It has the following controls:
4
2
1
3
Figure 2-17. 1500W AC Inverter
NOTE
The inverter operation is automatic. These
controls do not need to be manipulated for
normal operation.
On/Off Switch
1.
- This diagnostic slide switch
activates or terminates inverter operation. It should
remain in the on position.
Status LEDs
2.
- These LEDs indicate the operating
or fault status of the inverter.
15 Amp Circuit Breaker
3.
- In the event of a power
overload or circuit grounding, the circuit breaker
pops out. Press the breaker back in to reset.
GFCI Outlet
4.
- During inverter operation, this outlet
provides AC power.
Содержание 7127