CMANA00052 WMS Door Sensor Install Guide 

WMS Kit: 

  WMS 

  WMS Bracket 

  2, 8-32 by 5/16 Tamper Proof Screws 

 

6, 3/16 DIA Stainless Steel Rivets

 

  1, Activation Magnet 

  1, Strike Plate with VHB 

  4, Strike Plate Screws 

  3M Primer 94 Ampoule 

 

Tools Required: 

  Power Drill 

  3/16 Inch Drill Bit 

  1/8 Inch Drill Bit 

  Heavy Duty Blind Rivet Tool 

  T-15 

“Pin in Torx” Tamper Resist Screw Driver 

  #2 Phillips Screwdriver 

  50/50 Isopropyl Alcohol/Water Solution 

  Clean Rags 

 

WMS Door Sensor Installation Overview 

This guide is for the installation of the SkyBitz 
WMS Door Sensor on Dry Vans or Containers 
with swing doors.  The WMS will be mounted high 
on the door frame of the asset and will sense the 
ferrous steel of the door when it is closed.  The 
WMS will be mounted on the frame of the primary 
door if the asset has double doors.  If the door is 
nonferrous, a ferrous strike plate is included in 
the kit and will be mounted on the door.  Once 
installed, the WMS must be activated and 
calibrated to ensure the sensor is functioning 
properly after installation.  Please contact SkyBitz 
at 

[email protected]

 for help with any 

issues you may encounter with the installation of 
the SkyBitz WMS product. 

 

 

Install the WMS Mounting Bracket

 

With the door fully closed and latched, position 
the WMS Bracket as shown with the bracket 
pushed against the door.  Mark the upper and 
lower center hole locations.  Remove the bracket 
and use a 3/16 inch drill bit to drill the top hole. 

 

 

 

 

 

 

 

 

Содержание CMANA00052

Страница 1: ...ors The WMS will be mounted high on the door frame of the asset and will sense the ferrous steel of the door when it is closed The WMS will be mounted on the frame of the primary door if the asset has double doors If the door is nonferrous a ferrous strike plate is included in the kit and will be mounted on the door Once installed the WMS must be activated and calibrated to ensure the sensor is fu...

Страница 2: ...s steel rivet in the top center hole Push the bottom of the bracket against the door and use a 3 16 inch drill bit to match drill the lower center hole Install a 3 16 inch stainless steel rivet in the lower center hole Match drill the remaining four WMS bracket mounting holes Open the door and install the remaining four rivets to complete the bracket installation ...

Страница 3: ...entory mode to prohibit RF transmission and save battery power The WMS must be activated to make it operational Place the magnet as shown for 3 seconds and confirm both LEDs are blinking together This confirms the WMS is still in inventory mode and functioning properly Once the LEDs turn off after 10 seconds hold the magnet in the location shown again for at least 15 seconds The LED on the left wi...

Страница 4: ...rnating for about 10 seconds indicating a Door Open calibration reading is about to take place The LEDs will begin blinking together rapidly to signify they are taking a Door Open calibration measurement After about 10 seconds the LEDs will return to the alternating blink pattern for 30 seconds During this 30 second alternating blink pattern close and latch the door as the WMS waits to take a Door...

Страница 5: ...the calibration procedure ensuring all the steps are followed correctly 1 FCC Interference Statement Part 15 105 b This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and ...

Страница 6: ...il est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage 2 l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement 5 ISED Canada ICES 003 Compliance Label CAN ICES 3 B NMB 3 B ...

Отзывы: