53
Group “A” Fault Codes
- Continued
FAULT
CODE
SWING
SENSOR
BOOM
ANGLE
SENSOR
EXTENSION
SENSOR
Tdx 1
ROD
PRESSURE
Tdx 0
PISTON
PRESSURE
ACTION
016
X
Follow SECTION 3.10
017
X
X
Replace Computer
018
X
X
019
X
X
X
020
X
X
Follow SECTIONS 3.8.2,
3.8.3,
3.10
021
X
X
X
Replace Computer
022
X
X
X
023
X
X
X
X
024
X
X
Follow SECTIONS 3.8.6,
3.8.7,
3.10
025
X
X
X
Replace Computer
026
X
X
X
027
X
X
X
X
028
X
X
X
Follow SECTIONS 3.8.2,
3.8.3,
3.8.6, 3.8.7, 3.10
029
X
X
X
X
Replace Computer
030
X
X
X
X
031
X
X
X
X
X
3.3.2
Group “B” Fault Codes
Group “B” fault codes represent faults detected for internal analog functions and power feeds to the
function kickout and anti-two block switches.
The following chart details all of the available codes in the left column and the actions to take in the
right column.
FAULT CODE
FKO
POWER
FEED
A2B
POWER
FEED
ACTION
000
No Fault Found
Follow SECTION 3.10
008
X
Follow SECTION 3.9
016
X
Follow SECTION 3.5.3
024
X
X
Check crane circuit breakers, then
Follow
Section 3.5.3