DOL 834 CE
52
Technical User Guide
Select the required software version.
The installation process begins.
Settings are automatically saved before the update starts and
are loaded after the restart.
During the software update, the house controller will restart.
It is VERY important not to disconnect the power supply during update.
Do not remove the USB stick until the installation is fully completed. In other words, when the graphical user in-
terface is accessible and usable.
The software update is now complete.
If necessary, check the software version number via the menu
General | About | Software.
12.4.3 Check after software update
It is very important to check that the controller works as it did before the update, as a few connec-
tions may switch in connection with an update. The controller will provide a warning of this, but will
not indicate which connection has been moved.
If there are animals in the livestock house, it is very important to check the noted values after the
update, so that the day number and all other settings are correct again.
1.
Check the pages.
Compare the pages in the display with your notes or the pictures taken before the update. If you have lost
the setup, you have to set up the pages again.
2.
Check configuration after the update in the menu
Show connection
Check that the connections are as noted or as in the pictures taken before the update.
3.
Set/check that operation and climate values are the same as before the update according to the
notes entered in the form.
4.
Reset the climate components to automatic mode.
5. Check that the controller works as it should by testing all components.
This can be done in the menu
Manual/Auto
. You can test each function by activating manual mode.
6.
If the set-up has been copied from another house controller, all winch motors must be re-calibrated.
The controller will only load the calibration if it comes from the same house controller. Therefore, a calibra-
tion is required if it comes from another controller.
7.
Set the function
Use password
as required.
12.5 Control parameters
12.5.1 Control parameters
Central air intake
Select the menu
|
Technical | Service | Control parameters
Heating
Содержание DOL 834 CE
Страница 2: ......