![Skope VF1000-ICE Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/skope/vf1000-ice/vf1000-ice_service-manual_1289218080.webp)
80
Troubleshooting
Service Manual
SKOPE VF Series
9
Troubleshooting
Diagnostic Table
For questions about the electronic controller, see page 10. For problems with the cabinet and
refrigeration cassette, use the following table.
Cabinet
Refrigeration unit
Problem
Possible Cause
Suggestions
• Cabinet not operating
• No controller display
• Loss of power supply
• Check mains power supply.
• Interior light not on
• Light switched off
• Switch on at controller faceplate (see
page 11).
• Failed LED tube
• Replace LED tube (see page 54).
• Blown cabinet fuse
• Replace fuse (see page 66).
• Power consumption is higher
than expected
• Unit operating too hot
• Clean the condenser coil (see
page 79).
• Ensure the cabinet has good
ventilation around the refrigeration unit
(see page 50).
• Ensure the cabinet is in a cool spot.
• Cabinet doors are opened
excessively
• Ensure doors are closed more often.
• Unit and/or door seals
compromised
• Check unit and door seals and service
as necessary.
• Product is too warm
• Restricted airflow to cabinet
• Ensure product is not blocking airflow
slots.
• Ensure there is space around
individual product pieces.
• Warm cabinet temperatures
• Compressor operating for
long periods (more than 1
hour)
• Blocked condenser
• Clean the condenser coil (see
page 79).
• Poor ventilation around
refrigeration unit
• Ensure the cabinet has good
ventilation around the refrigeration unit
(see page 50).
• Unit and/or door seals
compromised
• Check unit and door seals and service
as necessary.
Problem
Possible Cause
Suggestions
• Compressor will not start: no
hum.
• Loss of power supply
• Replace fuse (see page 66). Check
reason.
• Overload protector tripped.
• Repair or replace control.
• Wiring improper, or loose.
• Check wiring against diagram (see
page 28).
• Faulty contactor
• Check and if necessary replace
contactor.
Continued over page