Replacement Procedures
Service Manual
Control and
Evaporator
Probes
The control probe is located on a bracket at the rear of the evaporator tub. The evaporator
probe is located on the right hand side of the evaporator pipe bends.
5. Unscrew the PIR sensor bracket
from the cabinet and detach the PIR
sensor from the bracket.
6. Unscrew and remove the front
upstand.
7. To remove the PIR sensor from the cabinet, pull the cable and up through the cabinet corner.
8. Following the same path as the original cable, fit the replacement PIR sensor assembly, connect
to the electrics box, and attach the sensor to the bracket and the bracket to the cabinet.
9. Reassemble the cabinet and check for correct operation by connecting to the fridge with the SCS
Field app and confirming ‘Motion’ appears when waving in front of the PIR sensor, and ‘No
Motion’ appears when there is no motion.
Procedure 26: To replace the PIR sensor (continued)
Procedure 27: To replace the control probe
Before you start
Make sure you take note of the original control probe cable’s path.
1. Disconnect the cabinet from the power supply (see page 18).
2. Remove the refrigeration cartridge (see page 28).
3. Remove the cartridge’s right side panel.
4. Remove the electrics box cover.
5. Unplug the control probe from the top of the electrics box (blue socket).
6. Remove the control probe from the cartridge. Cut cable ties where necessary.
7. Following the same path as the
original probe, run the new probe to
the original location, plug in to the
electrics box, and secure with cable
ties.