background image

12

Operation

User Manual

SKOPE BME ActiveCore

Electronic Controller

Introduction

The chiller is fitted with a Carel S4 electronic controller which is visible 
through a cutout in the cabinet front panel. The electronic controller is pre-
programmed and requires no initial setup or additional programming. 
SKOPE does not recommend that the settings be changed unless it is 
absolutely necessary. 

To achieve energy efficient operation, the electronic controller uses 
temperature probes and door switches to monitor chiller usage and switch 
the chiller between ‘Normal’ and ‘Energy Saving’ modes, control and display 
the chiller temperature, collect data, signal temperature alarms and force a 
defrost cycle when required.   

Faceplate

Because the electronic controller plays such an important role, it’s helpful to 
know the parts of the faceplate you may use.

CAUTION

The electronic controller must only be adjusted by an 

authorised service agent.

ES

1

2

3

4

5

6

8

7

No.

 Item

Description

1

Digital display of cabinet temperature or messages. The 
temperature is what the sensor inside the chiller detects, and 
not necessarily the product temperature. However, they may 
be very close depending on how the controller is set to sense 
temperature.

2

Energy Save (up):

 Button. Press to view the current chiller 

mode. ‘ECO’ = Energy Saving and ‘nor’ = Normal. Press and 
hold for 3 seconds to switch the chiller between ‘Energy 
Save’ and ‘Normal’ mode. 

3

Set (mute):

 Button. Press to mute the alarm. Press and hold 

to access parameters. 

4

Light (down):

 Button. Press and hold to switch the cabinet 

lights on and off.

5

Defrost:

 Indicator. ON when the defrost is activated. Flashes 

when the activation of the defrost is temporarily delayed due 
to procedures in progress.

6

Compressor: 

Indicator. ON when the compressor and 

condenser fan starts. Flashes when activation of the 
compressor is temporarily delayed.

7

Fan:

 Indicator. ON when the internal cabinet fans are 

activated. Flashes when activation of the fans is temporarily 
delayed.

8

Alarm:

 Indicator. ON when alarm is signalled.

ES

Содержание BME1200-AC

Страница 1: ...BME ActiveCore User Manual MAN11080 Rev 3 2 Oct 2015 BME1200 AC SKOPE Bottom Mount Vertical Chiller...

Страница 2: ...535 Australia 0800 947 5673 New Zealand SKOPE 1 year Extended Warranty Extend your Warranty Protection by 1 year during registration Please check you have not already organised an extended warranty th...

Страница 3: ...2 Operation Automatic Start Up 10 Lighting 10 LED Tube Side Light 10 LED Modular Shelf and Side Lighting 10 Sign Light 10 Loading Product 11 Electronic Controller 12 Introduction 12 Faceplate 12 Norma...

Страница 4: ...careful not to touch moving parts and hot surfaces For your own safety and that of others ensure that all electrical work is done by authorised personnel If the power supply flexible cord becomes dam...

Страница 5: ...ooting also prevents the condensate tray from overflowing Power Cord The chiller has a flexible power cord fitted with a 3 pin plug which exits the rear of the cabinet at floor level Locate the power...

Страница 6: ...at each end of the handle Rotate the handle so that the spring clips point up 3 Locate both of the handle mounts onto the brackets on the front of the door and push the handle down onto the brackets...

Страница 7: ...through the holes on the inside of the door frame and remove the handle 3 Remove the bracket s from the handle mount by pressing the bracket in and down until it unclips from the handle mount 4 Fit an...

Страница 8: ...d shelf position The support strips are numbered for easy location of shelf clips View the numbers in the bottom LH corner of the shelf clip To fit a shelf clip To slide a shelf clip up and down To re...

Страница 9: ...below To reposition shelves fitted with lights 1 Isolate the chiller from the power supply see Isolating Electrics on page 15 2 Remove product from the shelf required to be moved and from the shelf im...

Страница 10: ...mponent is suspected of being faulty a service call should be arranged so that a replacement component can be fitted Sign Light Cabinets with a lit sign are fitted with an LED tube located inside the...

Страница 11: ...space around each item to ensure even cooling and efficient operation of the chiller Do not exceed a maximum load of 20kg per shelf Remove some product if the shelves are flexing Do not let anything...

Страница 12: ...thorised service agent ES 1 2 3 4 5 6 8 7 No Item Description 1 Digital display of cabinet temperature or messages The temperature is what the sensor inside the chiller detects and not necessarily the...

Страница 13: ...net lights on and off 1 Press and hold the set button for 3 seconds until PS is shown on the display indicating entry into the controller settings menu 2 Press the down button to scroll the menu until...

Страница 14: ...isplay 3 Press the set button The current setpoint value is shown on the display 4 Press the up or down button to increase or decease the setpoint value to the required temperature 5 Press the set but...

Страница 15: ...unit compartment To isolate the electrics 1 Open the door and undo the fixing screws from the top of the front kick panel Pull the kick panel out to remove Note The electronic controller is attached t...

Страница 16: ...enser coil The optional filter is disposable and should be replaced when it shows signs of wear Do not apply hot water blow dry or place in dishwasher To clean the optional filter WARNING Isolate the...

Страница 17: ...er coil 1 Remove the front panel and isolate the chiller from the power supply see Isolating Electrics on page 15 2 Brush the condenser coil with a soft brush to remove any dust and fluff 3 Turn the i...

Страница 18: ...Sign Light BME600 AC and BME1200 AC chillers are fitted with a lit sign In the event of sign light failure a service call should be arranged so that a replacement LED tube can be fitted IMPORTANT DO...

Страница 19: ...aceplate or open the door Lights switched off Switch light on by pressing the light button on the electronic controller faceplate Failed LED tube Replace LED tube see page 17 Failed LED shelf light Co...

Страница 20: ...oduct after their state condition get up or packaging has been altered in any manner Alters removes including part removal or obliterates including part obliteration the trade mark on the product Appl...

Отзывы: