![Skope B550-2 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/skope/b550-2/b550-2_user-manual_1289186009.webp)
9
SKOPE B550/660-2 and BME550-2
Operation
User Manual
Electronic Controller
Controller
Display
Because the controller plays such an important role, it’s helpful to know the
parts of the faceplate you will use.
No.
Item
Description
1
Prg / mute:
To initiate programme sets, press for 5 seconds. Mutes the audible alarm
(buzzer) and deactivates the alarm relay.
2
UP / aux:
To scroll settings
UP
(in programme mode). Press and hold to switch light on or
off (some models only).
3
Set:
If pressed for more than 2 seconds displays and / or enables changing the temperature
setpoint (see page 16).
4
DOWN / def:
To scroll settings
DOWN
(in programme mode).
5
COMPRESSOR:
ON when the compressor and condenser fan starts. Flashes when activation of the
compressor is temporarily delayed.
6
FAN:
n.a.
7
DEFROST:
ON when the defrost is activated. Flashes when the activation of the defrost is temporarily
delayed due to procedures in progress.
8
AUX:
n.a.
9
ALARM:
Flashes in the event of alarms.
10
CLOCK:
n.a.
11
LIGHT:
Some models only.
12
SERVICE:
Flashes in the event of malfunctions.
13
DISPLAY:
Shows the cabinet temperature.
14
HACCP:
n.a.
15
CONTINUOUS CYCLE:
n.a.
Figure 7: Controller
Display