![Skope B550-2 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/skope/b550-2/b550-2_user-manual_1289186013.webp)
13
SKOPE B550/660-2 and BME550-2
Servicing
User Manual
Cleaning
When necessary, wipe the interior and exterior of the cabinet with a damp
cloth. Ensure the cabinet is disconnected from the mains power supply
before cleaning. Periodic cleaning of the condenser coil is also
recommended.
Condenser
coil
The condenser coil MUST be kept clean for efficient and reliable operation.
Clean the condenser coil with a brush and vacuum cleaner regularly. The
condenser coil is located behind a side baffle, on the right hand side of the
refrigeration unit.
To access the condenser coil
1. Isolate the cabinet from the mains power supply and remove the front
kick panel (see “Isolating Electrics” on page 12).
2. Remove the cabinet wiring junction box by loosening both the end
keyhole fixing screws.
3. Remove the two screws holding the side baffle to the condenser coil
and carefully pull the baffle out from the unit.
4. The condenser coil can now be accessed for cleaning. Clean the
condenser coil with a brush and vacuum cleaner.
5. Refit the side baffle and cabinet wiring junction box.
6. Refit the cabinet kick panel.
7. Reconnect the cabinet to the mains power supply.
Caution:
Disconnect the cabinet from the mains power supply before cleaning
the condenser coil.