![Skope B550-2 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/skope/b550-2/b550-2_user-manual_1289186011.webp)
11
SKOPE B550/660-2 and BME550-2
Operation
User Manual
Temperature
Setpoint
The chiller temperature setpoint is factory set at 2.0°C. If necessary the
standard setting can be adjusted between 1°C and 3.5°C (see below).
SKOPE do not recommend that the setpoint be changed unless it is
absolutely necessary, and then only by small increments at a time.
To view and adjust the temperature setpoint
:
1. To view the setpoint: press and hold the
SET
key for 2 seconds, until the setpoint value
flashes.
2. To adjust the setpoint: press either the
UP
or
DOWN
keys to display the required setpoint
value.
3. Press the
SET
key again to memorise the new
setpoint value. If this is not done within 60
seconds, changes will be lost and you will
need to repeat the above procedure.