Skope B070CB-1ROOS-E Скачать руководство пользователя страница 1

SKOPE Centaur Series

Horizontal and Vertical Chillers and Freezers

User Manual

MAN11086 R

ev

. 1.1 Apr.

 2015

 

Содержание B070CB-1ROOS-E

Страница 1: ...SKOPE Centaur Series Horizontal and Vertical Chillers and Freezers User Manual MAN11086 Rev 1 1 Apr 2015...

Страница 2: ...535 Australia 0800 947 5673 New Zealand SKOPE 1 year Extended Warranty Extend your Warranty Protection by 1 year during registration Please check you have not already organised an extended warranty th...

Страница 3: ...Castors 7 Shelving 7 Pans and Hinged Pan Covers 8 3 Operation Automatic Start Up 9 Power Switch 9 Refrigeration Unit 9 Electronic Controller 9 Electronic Controller 10 Introduction 10 Faceplate 10 St...

Страница 4: ...t Model Type Part No Doors Operating temperature range BC120 S Chiller B120 S 2RROS E 2 solid door 0 C to 4 C for up to 4 hours in 30 C ambient with hinged pan covers raised BC180 S B180 S 3RRRS E 3 s...

Страница 5: ...oving parts and hot surfaces For your own safety and that of others ensure that all electrical work is done by authorised personnel If the power supply flexible cord becomes damaged it must be replace...

Страница 6: ...warm draughts etc Allow adequate space for the door s and or drawer s to open fully Ensure the cabinet is positioned on a level surface so the door s shut and seal correctly and to prevent the conden...

Страница 7: ...d with shelves and shelf support brackets which can be positioned at different heights to suit various products To fit the shelves The cabinet should be left running for 30 minutes before loading with...

Страница 8: ...ommended operating ambient temperature for Sandwich and Pizza cabinets is 30 C Model Doors Pans Hinged pan covers BC120 S 2 doors 6 1 3 refrigerated pans 176mm wide 325mm deep 1 BC180 S 3 doors 9 1 3...

Страница 9: ...the cabinet is plugged in This may be verified by listening for compressor switch on and checking for air movement inside the cabinet The compressor and condenser fan will switch off when the cabinet...

Страница 10: ...es not recommend that the settings be changed unless it is absolutely necessary Faceplate Because the electronic controller plays such an important role it s helpful to know the parts of the faceplate...

Страница 11: ...ss for more than 5 seconds to initiate manual defrost To scroll settings down in program mode 5 Compressor ON when the compressor and condenser fan starts Flashes when activation of the compressor is...

Страница 12: ...and stop when action is taken to resolve the problem Note The messages and alarms differ between the CAREL Easy electronic controller and the CAREL ir33 electronic controller Refer to the relevant tab...

Страница 13: ...l see page 14 2 Check refrigeration ventilation Ensure clear airpath in front of the cabinet 3 Ensure the cabinet is installed in a suitable environment 4 To reset the CHt alarm unplug the cabinet fro...

Страница 14: ...TION Unplug the cabinet from the mains power supply before cleaning the condenser coil or washing the cabinet with water 1 Isolate the cabinet from the power supply by unplugging it from the wall 2 Op...

Страница 15: ...ght type 25W bulb OSRAM PYGMY CL25E14 15W T8 fluorescent tube Centre pillar LED strip light 1 Isolate the cabinet from the power supply by unplugging it from the wall 2 Unscrew and remove the light co...

Страница 16: ...round the refrigeration unit Cabinet doors are opened excessively Keep door s open for minimum time 3 Product is too warm and spoiling Restricted cabinet airflow Ensure product is not blocking airflow...

Страница 17: ...uct after their state condition get up or packaging has been altered in any manner Alters removes including part removal or obliterates including part obliteration the trade mark on the product Applie...

Отзывы: