EML224N Operation and Installation Manual
SKIPPER
Electronics AS
Edition: 2020-22-05
Page 19 of 64
Chapter: 2. Operation
Fig. 2.9. Screen Status, Menu 2
Soft key Name
Range/value
Default
value
Description
Activate with
hidden button
1
MENU
1 - 6
2
Chosen menu number 2.
2
OUT NUM
1 - 3
1
Pulse output channel to be configured by soft
keys 3 and 4.
3
PULSES NUM 10, 100, 200,
400, (1000)/nm
400/nm
Number of pulses per nautical mile at
this channel (key 2). Channel 1 and 2 are
programmable with 10, 100, 200 and 400
pulses per nautical mile. Channel 3 are
programmable with 10, 100, 200, 400 and
1000 pulses per nautical mile.
4
OUT MODE
ResultWT,
ForAftWT,
LateralWT,
ResultWT Speed parameter to be output at this channel
(soft key 2).
5
Not used.
6
Not used.
Note:
1000 pulses per nautical mile only on Ch 3 (OUT NUM 3).