Page 14 of 48
Date: 2021-12-10
Date: 20121-10-10
Page 15 of 48
InMan DL1-Multi Single Axis Doppler Speed Log System
InMan DL1-Multi Single Axis Doppler Speed Log System
Electronics AS
Electronics AS
p
LaceMenT
of
The
eLecTronic
uniT
(JB70D1-XX)
All parts of the system are connected to the electronic unit.
Power, Control unit, Sensor, all I/O signals (alarm, NMEA,puls out etc)
Access to Electronic unit only needed for service.
Placement is typically in or near the bridge where the interfaced systems are available, but no
nearer than 0.3 m to the GYRO heading sensor.
115
114
109
123
A
181
218
Installl a mounting DIN rail EN 50022 (if not existing) on the wall.
1.
Mount the JB70D1-XX on the rail. (Be sure that the unit is properly mounted, see detalil A)
2.
Mark the 4 centerpoints for the drill in the wall (A).
3.
NB! The drilling holes diam. depends on thickness and material of the wall.
Use self tapping screws ST3,5 DIN 7981-C pozidrive (A). (The screw length depends on the wall thickness).
4.
Mounting DIN rail EN 50022 (min. 260 mm)
A
7,6
DETAIL A
SCALE 2 : 1
IP22 approved mounting
E
F
C
1
2
3
4
B
A
3
2
1
5
C
D
4
6
7
8
A
B
Electronics AS
D
E
ISO2768m
1:2
Gen. tolerance
Eur. projection
XXX
Material
2013.04.29
Checked by
XX-XXX XX
Date
CN
Drwg. no.
Name
XXX
Edition date
Sheet
X0
Revision
XXX
Scale
JB70D1-SA mounted at wall
1 of 1
Designed by - date
XXX
A.Matre 2012.11.27
Approved by - date
p
LaceMenT
of
The
conTroL
uniT
(cD402cu-XX)
If required, the control unit is placed on the bridge. Some standards require
some operations of the unit to be available from ‘standing position’, and in
this case the unit must be near the steering position. However, it is also
possible to control some of these settings from multi-repeaters with 2-way
communication (ex: CD401MR-SB) In which case, the Control unit can be
placed on, for example, the navigation table.
p
LaceMenT
of
repeaTers
cD401Mr-XX
Repeaters are typically installed on the overhead console and/or the bridge wings. These can be
routed using NMEA signals These require a local +24 V DC supply.
Same dimensions as CD402.
Menu
Menu
Set
1
2
3
4
144 [5,669]
Power consuption: 24 VDC/ 3W
Protection code: IP56
COMPACT DISPLAY
SKIPPER
Set
60 mm
Recomended plug
distance: