CHAPTER 7: TROUBLE SHOOTING
c
onTroL
u
niT
cD402 T
rouBLe
shooTing
.
Check that a red dot is blinking in right top corner of display.
This is indication of processor being OK.
“ERROR”.
CD402CU does not detect the JB70D1-XX unit
Check that Electronic unit is powered
Check LAN cabling from Display to Electronic unit.
Check port and IP set up “Chapter 3: Setup LAN Communication” on
“ERROR COM”.
CD402CU detects the JB70D1-XX unit but JB70D1 is sending message
that it does not receive any message from CD402CU.
“STW ERROR
No or invalid data from sensor.
STATUS LED 1
(Green)
Not in use
STATUS LED 2
(Yellow)
Not in use
STATUS LED 3
(Green)
SW up to ver 1.57:
ON. OK
SW from ver 1.58
Blinking 1Hz receive sensor signal
Blink every 5 Second. No sensor signal
e
LecTronic
u
niT
JB70D1 D
iagnosTics
Input power OK
Both LEDs lit when 24VDC or 115/220VAC
detected.
LAN Power
(Green)
Lit when Display is powered over LAN.
LAN data
(Yellow)
LAN detected
(Yellow)
Screen update indicator
(Green)
Blinks aech screen update..
NMEA In
(Green)
Sensor Signal In
(Green)