SKIPLY Smilio Action Скачать руководство пользователя страница 1

 

 

 

 

User Manual 

Smilio S - FW 2.0.1.4 

 

 

 

Test our Smilio S simulator 

 

https://skiplyfrance.github.io/simulatorS.html

 

Содержание Smilio Action

Страница 1: ...User Manual Smilio S FW 2 0 1 4 Test our Smilio S simulator https skiplyfrance github io simulatorS html...

Страница 2: ...n of your Smilio S please read carefully and follow the instructions contained in this user manual SKIPLY SAS Rue Henri Bouvier 73630 LE CHATELARD France Phone 33 4 79 52 29 31 Technical support 33 4...

Страница 3: ...equirements 7 5 Environment 7 6 Contact information 7 7 LoRa or SIGFOX configuration 8 8 Insert or replace batteries 9 9 Boot sequence 10 9 1 Sigfox boot sequence 10 9 2 Sigfox Downlink Query 11 9 3 L...

Страница 4: ...at join procedure Useable only with LoRaWAN 21 15 2 Backoff parameters Useable only with LoRaWAN 21 15 3 Piggyback Useable only with LoRaWAN 22 16 Running Mode description 23 16 1 Running Mode 6 23 16...

Страница 5: ...tute goods or services loss of use data or profits or business interruption however caused and on any theory of liability arising in any way out the use of the hardware and software 1 3 Applications A...

Страница 6: ...ady Certified on major LoraWan networks Objenious Orange Certified on Sigfox networks Easy to use and deploy 5 AA limited power 3 6 V Primary lithium thionyl chloride Li SOCl2 batteries IP65 certified...

Страница 7: ...fx_pac Network LoRa WAN and or SIGFOX coverage the indoor and outdoor coverage can be different Please check the real coverage Phillips screwdriver NOTE To obtain the LoRa SIGFOX IDs please contact ou...

Страница 8: ...oRa or SIGFOX configuration To configure the network LoRa or SIGFOX please use the jumper on the motherboard behind the battery compartment lid Figure 1 NOTE Before remove or place the jumper remove a...

Страница 9: ...ed by an incorrect or non recommended type 1 Before opening the battery compartment lid if moisture or water drops are present dry Smilio S housing with clean soft towel 2 Open the battery compartment...

Страница 10: ...ly red for 3 seconds The red color doesn t mean that updating and restart have failed but that the stored settings aren t updated twice in a row Boot without updating settings o Preconditions a valid...

Страница 11: ...ocess For more details please refer to the LoRaWAN specifications which can be downloaded on the LoRa Alliance website If a payload exists in the downlink queue this payload is pushed from the backend...

Страница 12: ...rocess the radio parameters are exchanged between the backend and the device Channels Spreadfactor SF etc Making a new join and a downlink process in Sigfox Restart the Smilio S without opening the ba...

Страница 13: ...a monitoring data frame This frame contains Battery voltage in idle mode Battery voltage in emission Tx The frame format is 01 XXXX YYYY 64 01 Keep Alive data frame XXXX Battery voltage in idle mode h...

Страница 14: ...data frame AAAA button 1 incremental counter value BBBB button 2 incremental counter value CCCC button 3 incremental counter value DDDD button 4 incremental counter value EEEE button 5 incremental co...

Страница 15: ...emental counter value DDDD button 4 incremental counter value EEEE button 5 incremental counter value Example of Normal Data Frame 03 0001 0010 00A0 0023 0010 03 Acknowledge data frame 0001 incrementa...

Страница 16: ...c badge detections seconds 3 60 csc Only valid and useable in Periodic Send Mode for energy saving 0 send a frame 02 at each end of period whatever the counter values 1 send a frame 02 at each end of...

Страница 17: ...on 3 4 5 During tpb a single push permitted on the same button 6 RNM 2 with acknowledgement For details please refer to paragraph 16 7 RNM 9 CODE with acknowledgment For details please refer to paragr...

Страница 18: ...between two pushes and frame 02 is sent out automatically every dtx minutes backup function whatever the counter values 0x12 Frame 02 is sent out at each push with a delay of tpb between two pushes a...

Страница 19: ...of tpb between two pushes and frame 02 is sent out automatically every dtx minutes backup function whatever the counter values 0x12 Frame 02 is sent out at each push with a delay of tpb between two pu...

Страница 20: ...KIPLY SAS and may neither be used nor disclosed without its prior written consent 20 14 4 Online Downlink Frame configurator To help you to generate a valid downlink frame you can use our online confi...

Страница 21: ...N networks are able to manage the Smilio S s data rate ADR should be enabled whenever an end device has sufficiently stable RF conditions This means that it can generally be enabled for static devices...

Страница 22: ...lio S responds to MAC commands from the network Therefore the transmitted frame contains only the response to the MAC command port 0 When the Piggyback is enabled and the response to the MAC command i...

Страница 23: ...ntil the timeout is ended the keyboard is disabled User have to wait to use keyboard Note After the time out of 60 second if LEDs lights red fix it isn t a proof that the payload didn t received by th...

Страница 24: ...by the network server After expiration of TPB the Smilio S flash alternatively red green until the acknowledge is received Two cases Acknowledgement from network server is received by Smilio S LEDs l...

Страница 25: ...The frame format is 40 AAAA BBBB CCCC DDDD EEEE 40 Mode PULSE data frame AAAA button 1 incremental counter value max 0001 BBBB button 2 incremental counter value max 0001 CCCC button 3 incremental cou...

Страница 26: ...he countdown equal to TPB LEDs lights green fix to inform user that it is possible to compose a new code For an acknowledged code the header of the uplink payload starts with 3 For an unacknowledged c...

Страница 27: ...h acknowledgement second without acknowledgement o 33 two codes first with acknowledgement second with acknowledgement Example of CODE Data Frame Just after first start or after hard reset if user ent...

Страница 28: ...tten consent 28 17 Dimensions Weight with batteries 400 grs Plastics ABS Acrylonitrile Butadiene Styrene Copolymer Flammability V0 IEC 60695 11 10 ANSI UL 94 Gasket Thermoplastic Vulcanizate TPE famil...

Страница 29: ...only batteries AA approved LiSOCl2 3 6V There is a risk of explosion if battery is replaced by incorrect type 19 Symbols Caution risk of danger or Attention Follows operating instructions See user man...

Страница 30: ...European directives 2014 35 UE and RED 2014 53 EU Smilio S complies with these European Standards and Directives Electromagnetic Compatibility EMC ETSI EN 301 489 3 2017 v2 1 1 and ETSI EN 301 489 1...

Страница 31: ...mation and data contained in this document are the exclusive property of SKIPLY SAS and may neither be used nor disclosed without its prior written consent 31 21 Certificates 21 1 Sigfox Ready certifi...

Страница 32: ...ll information and data contained in this document are the exclusive property of SKIPLY SAS and may neither be used nor disclosed without its prior written consent 32 21 2 Sigfox Ready certificate RC2...

Страница 33: ...ll information and data contained in this document are the exclusive property of SKIPLY SAS and may neither be used nor disclosed without its prior written consent 33 21 3 Sigfox Ready certificate RC3...

Страница 34: ...All information and data contained in this document are the exclusive property of SKIPLY SAS and may neither be used nor disclosed without its prior written consent 34 21 4 IP 65 Certification...

Отзывы: