7
EN
7. Setup and fieldbus configuration on MQL system
6
- 85 -
951-170-218-EN
Version 06
7. Setup and ieldbus coniguration on MQL system
7.1 Adjustment elements
On delivery, MQL systems are already con-
figured with typical settings so that only
a few configuration steps are required to
ready them for service.
Each control unit has an LED display and
adjustment elements protected by an acrylic
glass pane. During operation, the LED dis-
play (
2
) shows the number of the lubrication
program invoked by the machine tool. The
operating elements are meant for configu-
ration of the MQL system, which is usually
necessary only during commissioning. This
requires removal of the acrylic glass pane.
See Figure 48 and Table 6
• Remove screws (3x) from the acrylic glass
pane using a hexagon socket screw key
(WAF 2.5).
• Remove the acrylic glass pane.
• Configure the system using the 8-position
DIP switch (
1
).
• Set the desired PROFIBUS address using
the rotary decade switches (
3
).
Controls, Fig. 48
Legend to Fig. 48
Plug
Function
1
DIP switch, 8-position
2
LED display, 4-digit
3
Rotary decade switches
3
2
1
STR
7
6
5
4
8
0
9
8
7
6
5
4
3
2
1
6
5
4
3
2
9 0 1
7
8
1
2
3