SKF Multilog On-Line System IMx-M
7 - 1
User Manual
7
Technical Data
Environmental
19" rack mounted, 6U high
Size (height x width x depth): 266 x 482 x 240 mm (10.5 x 19 x 9.4 in.)
Weight: 13,6 kg (30 lb.) for a fully equipped rack
Temperature range:
–
20 to +70 °C (
4 to +158 °F
) in storage
–
20 to +65 °C (
4 to +149 °F
) in operational mode
Encapsulation IP 20
Humidity 95% (relative) non-condensing
Overvoltage category II
Pollution degree 2
Altitude maximum 2 000 m (6 562 ft.)
Rack
2 Power Supply Units
4 condition monitoring modules and 4 protection modules (always mounted in
pairs)
3 relay modules
Screw terminals, RJ45 and D-sub connectors on the rear
Event Log: minimum of 1 400 latest events can be stored on each CMM + PRM slot
Power Supply
90 to 240 VAC, 47 to 63 Hz, 300 W maximum
Redundant option, individual mains terminals