background image

Electronic air shutoff 

assembly

Model V340HH

Installation/Operation guide

Read manual prior to installation or use 
of this product. Keep manual nearby for 
future reference. Failure to follow 
instructions and safety precautions may 
result in death or serious injury. 

D A N G E R

Date of issue 

January 2015

Form number 

404633A

Section 

F60

Page 

77A

Содержание Lincoln V340HH

Страница 1: ...uide Read manual prior to installation or use of this product Keep manual nearby for future reference Failure to follow instructions and safety precautions may result in death or serious injury DANGER...

Страница 2: ...r s recommendations regarding fluid compatibility and the use of protective clothing and equipment Failure to comply may result in personal injury and or damage to equipment Wear adequate personal pro...

Страница 3: ...nuously monitored by a Programmable Control Board PCB for correct operating cycles If the pump cycles exceed PCB settings a solenoid is activated which utilizes compressed air to shutoff pump operatio...

Страница 4: ...er back cover 3 remain connected Notice Save original rectangular plate 10 for future use Installation 1 Turn off pump 2 Remove four screws 9 and top plate 10 from module on back of pump fig 1 Fig 2 F...

Страница 5: ...socket 26 5 Pry out DIN socket insert 33 from DIN socket housing 32 using a small flat head screwdriver 6 Referring to fig 4 thread wiring from PLC or other remote monitor through cap 27 washers 28 2...

Страница 6: ...eck this or any error press B 21 Run mode Refer to table 3 for run mode options Once overrun controller is properly installed press A 20 fig 5 to start pump When pump is running without any errors gre...

Страница 7: ...4 for overrun mode options Hold A 20 for 5 seconds to reset overrun error condition fig 5 pg 6 Sleep mode The overrun controller enters sleep mode when it does not receive any pressure switch signals...

Страница 8: ...er of the circuit board 7 Disconnect old battery from snap connector 8 Connect new 9 V battery to snap connector 9 Insert battery back into void in lower right corner of circuit board 10 Press and rel...

Страница 9: ...deactivate pump off Blue 250 mA 12 V DC Solenoid common Black 250 mA 12 V DC Solenoid activate pump on Grey 250 mA 12 V DC Pressure switch signal Orange 1 mA 5 V DC Pressure switch supply Red 10 mA 5...

Страница 10: ...1 Pressure switch kit 286425 2 Mounting plate kit 286431 right side 286431 left side 3 PCB enclosure kit 286427 4 Solenoid valve kit 286428 5 Valve cap assembly kit 286429 6 End plug kit 286424 7 Seal...

Страница 11: ...72 85782 and replacement injectors 85771 85781 Lincoln warrants the SL V Injector series to be free from defects in material and work manship for two 2 years following the date of purchase If an injec...

Страница 12: ...equipment reliabil ity optimizing operational and energy efficiency and reducing total cost of ownership These competence areas include bearings and units seals lubrication systems mechatronics and a...

Отзывы: