9.1.1 Three-digit LED display
The display is off in normal mode. It can be
activated by briely pressing one of the two
pushbuttons
. Current values and pre-
set parameters are displayed. The display also
serves to guide and prompt the operator while
programming operating parameters.
Device display - three-digit LED display
9. Display and control unit
Three-digit LED display
Display Meaning
Statement
Control function
t
= TIMER
PA
= PAUSE
c
= COUNTER
PA
= PAUSE
t
= TIMER
CO
= CONTACT
c
= COUNTER
CO
= CONTACT
C
= Cycle
O
= OFF
P
= Pressure
Monitoring OFF
C
ycle
S
witch, piston
detector
(progressive
systems)
The control unit is functioning
as a timer and is currently in
PAUSE mode.
The control unit is functioning as a
counter and is currently in PAUSE
mode.
The control unit is functioning as
a timer and is currently in a pump
cycle (CONTACT).
The control unit is functioning as a
counter and is currently in a pump
cycle (CONTACT).
Display the "Monitoring settings"
menu
The CS and PS monitoring func-
tions are switched off.
Piston detector monitoring is
active.
Part of lubrication cycle; entry
and display value in hours.
Part of the lubrication cycle; the
device counts the pulses from
the external timer and compares
them with the pre-set values.
CONTACT = time during which
the pump delivers lubricant;
entry and display value in
minutes.
CONTACT = time during which
the pump delivers lubricant;
entry and display value in pulses.
No system monitoring
The piston detector is monitored
for signals during the CONTACT
pump cycle.