7.3.5 Display and documentation functions
During system operation, current operational
data (status data) is stored in the FRAM and
can be read at any time.
If the control unit is switched off or loses
power, the most recent status data remains in
the FRAM. When the control unit is turned on
again, it reads the saved data and the lubrica-
tion process continues where it left off, unless
the coniguration has been changed.
All faults detected by the lubrication system's
monitoring functions are also given a time
stamp and stored persistently in the control
unit's non-volatile memory area.
7.3.6 Conigurable parameters
The control unit contains 16 sets of param-
eter data. A parameter set contains all the
information required to control and monitor
the lubrication process, e.g., the number of
lubrication zones, the interval times, the pump
cycle times, etc.
7. Functional description in single-line systems