Assembly instructions
4.4.2 Filler coupling
As an alternative or addition to a conical head
nipple (
1
), the unit can also be equipped with a
iller socket (part No. 995-000-705) (
2
) to ill
using a illing pump. A corresponding coupling
socket (part No. 995-001-500) (
3
) must be
mounted on the illing pump. The cap on the
iller socket must be removed before illing.
Filling via filler coupling
4.4.3 Filling cylinder
The pump unit can also be illed through one
of the lubricant outlets using a illing cylinder
(
1
). To do this, remove the M20x1.5 screw plug
(
2
) in the lubricant outlet and replace it with a
iller socket (part No. 169-000-174) (
3
). The
caps (
4
) on the socket and illing cylinder must
be removed before illing.
4.4.4 Filling cover
A special design for the pump units is illed
with lubricant through a special hinged lid or a
screw cap.
Filling via filling cylinder
Only ill using clean lubricant and an
appropriate illing device. Not suitable in
case of highly contaminated pumps and
surrounding areas.
Filling cover versions
995-000-705
995-001-500
KFG3-5; KFGS3-5
KFG5-5; KFGS5-5
KFG1-5W2; KFGS1-5W2
(for NLGI Grade 1 greases)
KFGS1-5
Filler socket
169-000-174
Filling cylinder
169-000-171